Proton Light Yield of Fast Plastic Scintillators for Neutron Imaging
- 16 December 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (2), 434-442
- https://doi.org/10.1109/tns.2019.2959979
Abstract
Plastic organic scintillators have been tailored in composition to achieve ultra-fast temporal response, thereby enabling the design and development of fast neutron detection systems with high timing resolution. Eljen Technology’s plastic organic scintillators–EJ-230, EJ-232, and EJ-232Q– are prospective candidates for use in emerging neutron imaging systems, where fast timing is paramount. To support the neutron response characterization of these materials, the relative proton light yields of EJ-230, EJ-232, and EJ-232Q were measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-offlight technique, the proton light yield relations were obtained over a proton recoil energy range of approximately 300 keV to 4 MeV. The EJ-230, EJ-232, and EJ-232Q scintillators exhibited similar proton light yield relations to each other as well as to other plastic scintillators with the same polymer base material. A comparison of the relative proton light yield of different sized cylindrical EJ-232 and EJ-232Q scintillators also revealed consistent results. This work provides key input data for the realistic computational modeling of neutron detection technologies employing these materials, thereby supporting new capabilities in near-field radionuclide detection for national security applications.Keywords
Funding Information
- Lawrence Berkeley National Laboratory (DE-AC02-05CH11231)
- Office of Defense Nuclear Nonproliferation (DE-NA0003180)
This publication has 24 references indexed in Scilit:
- Reaching time resolution of less than 10 ps with plastic scintillation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomographPhysics in Medicine & Biology, 2016
- Calibration of time of flight detectors using laser-driven neutron sourceReview of Scientific Instruments, 2015
- Characterization of a cubic EJ-309 liquid scintillator detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Picosecond resolution on relativistic heavy ions' time-of-flight measurementNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- Neutron light output response and resolution functions in EJ-309 liquid scintillation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- An LED pulser for measuring photomultiplier linearityNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- Physical description of nuclear materials identification system (NMIS) signaturesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- ROOT — An object oriented data analysis frameworkNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- Gamma-calibration of NE 213 scintillation countersNuclear Instruments and Methods in Physics Research, 1982