Clinical Evaluation of Highly Accelerated Compressed Sensing Time-of-Flight MR Angiography for Intracranial Arterial Stenosis
Open Access
- 1 October 2018
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal Of Neuroradiology
- Vol. 39 (10), 1833-1838
- https://doi.org/10.3174/ajnr.A5786
Abstract
BACKGROUND AND PURPOSE: Time-of-flight MR angiography is the preferred imaging technique to assess intracranial arterial stenosis but is limited by a relatively long acquisition time. Compressed sensing provides an innovative approach in undersampling k-space to minimize the data-acquisition time. We aimed to evaluate the diagnostic accuracy of compressed sensing TOF for detecting intracranial arterial stenosis by comparison with conventional parallel imaging TOF-MRA. MATERIALS AND METHODS: Compressed sensing TOF and parallel imaging TOF were performed in 22 patients with intracranial arterial stenosis. The MRA scan times were 2 minutes and 31 seconds and 4 minutes and 48 seconds for compressed sensing TOF and parallel imaging TOF, respectively. The reconstructed resolutions were 0.4 x 0.4 x 0.4 and 0.4 x 0.4 x 0.6 mm(3) for compressed sensing TOF and parallel imaging TOF, respectively. The diagnostic quality of the images and visibility of the stenoses were independently ranked by 2 neuroradiologists blinded to the type of method and were compared using the Wilcoxon signed rank test. Concordance was calculated with the Cohen . Edge sharpness of the arteries and the luminal stenosis ratio were analyzed and compared using a paired-sample t test. RESULTS: The interrater agreement was good to excellent. Compressed sensing TOF resulted in image quality comparable with that of parallel imaging TOF but boosted confidence in diagnosing arterial stenoses (P = .025). The edge sharpness of the intracranial arteries for compressed sensing TOF was significantly higher than that for parallel imaging TOF (P < .001). The luminal stenosis ratio on compressed sensing TOF showed no significant difference compared with that on parallel imaging TOF. CONCLUSIONS: Compressed sensing TOF both remarkably reduced the scan time and provided adequate image quality for the diagnosis of intracranial arterial stenosis.This publication has 25 references indexed in Scilit:
- Compressed Sensing 3-Dimensional Time-of-Flight Magnetic Resonance Angiography for Cerebral AneurysmsInvestigative Radiology, 2016
- Heart Disease and Stroke Statistics—2016 UpdateCirculation, 2016
- Intracranial AtherosclerosisStroke, 2011
- A Prospective Trial of 3T and 1.5T Time-of-Flight and Contrast-Enhanced MR Angiography in the Follow-Up of Coiled Intracranial AneurysmsAmerican Journal of Neuroradiology, 2009
- Autopsy Prevalence of Intracranial Atherosclerosis in Patients With Fatal StrokeStroke, 2008
- Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3TJournal of Magnetic Resonance Imaging, 2008
- Multidetector CT angiography in the assessment of peripheral arterial occlusive disease: accuracy in detecting the severity, number, and length of stenosesEuropean Radiology, 2007
- Comparison of CT and Catheter Arteriography for Evaluation of Peripheral Arterial DiseaseVascular and Endovascular Surgery, 2005
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- MR angiography of the carotid bifurcation: artifacts and limitations.American Journal of Roentgenology, 1994