Preliminary Data Using Computed Tomography Texture Analysis for the Classification of Hypervascular Liver Lesions
- 1 February 2015
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Computer Assisted Tomography
- Vol. 39 (3), 383-395
- https://doi.org/10.1097/rct.0000000000000217
Abstract
Computed tomography texture analysis (CTTA) is a method of quantifying lesion heterogeneity based on distribution of pixel intensities within a region of interest. This study investigates the ability of CTTA to distinguish different hypervascular liver lesions and compares CTTA parameters by creating a proof-of-concept model to distinguish between different lesions.Following institutional review board approval, CTTA software (TexRAD Ltd) was used to retrospectively analyze 17 cases of focal nodular hyperplasia, 19 hepatic adenomas, 25 hepatocellular carcinomas, and 19 cases of normal liver parenchyma using arterial phase scans. Two radiologists read the same image series used by the CTTA software and reported their best guess diagnosis. Computed tomography texture analysis parameters were computed from regions of interest using spatial band-pass filters to quantify heterogeneity. Random-forest method was used to construct a predictive model from these parameters, and a separate regression model was created using a subset of parameters.The random-forest model successfully distinguished the 3 lesion types and normal liver with predicted classification performance accuracy for 91.2% for adenoma, 94.4% for focal nodular hyperplasia, and 98.6% for hepatocellular carcinoma. This error prediction was generated using a subset of data points not used in generation of the model, but not on discrete prospective cases. In contrast, the 2 human readers using the same image series data analyzed by the CTTA software had lower accuracies, of 72.2% and 65.6%, respectively. The explicit regression model with a subset of image parameters had intermediate overall accuracy of 84.9%.Computed tomography texture analysis may prove valuable in lesion characterization. Differentiation between common hypervascular lesion types could be aided by the judicious incorporation of texture parameters into clinical analysis.Keywords
This publication has 25 references indexed in Scilit:
- Three-dimensional positron emission tomography image texture analysis of esophageal squamous cell carcinomaNuclear Medicine Communications, 2013
- Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice?Insights into Imaging, 2012
- Tumour heterogeneity in oesophageal cancer assessed by CT texture analysis: Preliminary evidence of an association with tumour metabolism, stage, and survivalClinical Radiology, 2012
- Tumour heterogeneity in non-small cell lung carcinoma assessed by CT texture analysis: a potential marker of survivalEuropean Radiology, 2011
- Dynamic Contrast-Enhanced Texture Analysis of the LiverInvestigative Radiology, 2011
- Texture analysis of non-small cell lung cancer on unenhanced computed tomography: initial evidence for a relationship with tumour glucose metabolism and stageCancer Imaging, 2010
- Texture analysis in non-contrast enhanced CT: Impact of malignancy on texture in apparently disease-free areas of the liverEuropean Journal of Radiology, 2009
- Texture Analysis of Aggressive and Nonaggressive Lung Tumor CE CT ImagesIEEE Transactions on Biomedical Engineering, 2008
- Hepatic Enhancement in Colorectal Cancer: Texture Analysis Correlates with Hepatic Hemodynamics and Patient SurvivalAcademic Radiology, 2007
- In Search of Biologic Correlates for Liver Texture on Portal-Phase CTAcademic Radiology, 2007