Optimum Waveforms for Differential Ion Mobility Spectrometry (FAIMS)
- 30 September 2008
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 19 (9), 1286-1295
- https://doi.org/10.1016/j.jasms.2008.05.008
Abstract
Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) is a new tool for separation and identification of gas-phase ions, particularly in conjunction with mass spectrometry. In FAIMS, ions are filtered by the difference between mobilities in gases (K) at high and low electric field intensity (E) using asymmetric waveforms. An infinite number of possible waveform profiles make maximizing the performance within engineering constraints a major issue for FAIMS technology refinement. Earlier optimizations assumed the non-constant component of mobility to scale as E2, producing the same result for all ions. Here we show that the optimum profiles are defined by the full series expansion of K(E) that includes terms beyond the first that is proportional to E2. For many ion/gas pairs, the first two terms have different signs, and the optimum profiles at sufficiently high E in FAIMS may differ substantially from those previously reported, improving the resolving power by up to 2.2 times. This situation arises for some ions in all FAIMS systems, but becomes more common in recent miniaturized devices that employ higher E. With realistic K(E) dependences, the maximum waveform amplitude is not necessarily optimum, and reducing it by up to ∼20% to 30% is beneficial in some cases. The present findings are particularly relevant to targeted analyses where separation depends on the difference between K(E) functions for specific ions.Keywords
This publication has 35 references indexed in Scilit:
- Differential Mobility Separation of Ions Using a Rectangular Asymmetric WaveformThe Journal of Physical Chemistry A, 2008
- Evaluation of high‐field asymmetric waveform ion mobility spectrometry coupled to nanoelectrospray ionization for bioanalysis in drug discoveryRapid Communications in Mass Spectrometry, 2007
- Analysis of nitrosamines by capillary electrospray‐high‐field asymmetric waveform ion mobility spectrometry‐MS with programmed compensation voltageElectrophoresis, 2007
- The role of conformation on electron capture dissociation of ubiquitinJournal of the American Society for Mass Spectrometry, 2006
- High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry AnalyzersAnalytical Chemistry, 2006
- Simultaneous analysis of prostanoids using liquid chromatography/high‐field asymmetric waveform ion mobility spectrometry/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Characterizing the Structures and Folding of Free Proteins Using 2-D Gas-Phase Separations: Observation of Multiple Unfolded ConformersAnalytical Chemistry, 2006
- Feasibility of Higher-Order Differential Ion Mobility Separations Using New Asymmetric WaveformsThe Journal of Physical Chemistry A, 2006
- Species-Specific Bacteria Identification Using Differential Mobility Spectrometry and Bioinformatics Pattern RecognitionAnalytical Chemistry, 2005
- Qualitative analysis of trace constituents by ion mobility increment spectrometerTalanta, 2003