Six-year follow-up of laser in situ keratomileusis for moderate and extreme myopia using a first-generation excimer laser and microkeratome
- 1 June 2003
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Cataract & Refractive Surgery
- Vol. 29 (6), 1152-1158
- https://doi.org/10.1016/s0886-3350(03)00062-2
Abstract
To evaluate objectively and subjectively the long-term outcome of laser in situ keratomileusis (LASIK) in patients with high and very high myopia. Department of Ophthalmology, Philipps University, Marburg, Germany. Thirty-three eyes of 19 patients were followed for a mean of 76 months (range 50 to 84 months) after primary LASIK using the Keratom I excimer laser (Schwind) and the ALK microkeratome (Chiron). Refraction, glare, pachymetry, corneal topography, and tear-film secretion and stability were measured. At the last examination, patients also answered a 14-item questionnaire. Preoperatively, the mean spherical equivalent was -13.65 diopters (D). At 1 year, it was -0.25 D and after 6 years, -0.88 D. Fifteen percent of eyes lost > or =2 lines of best spectacle-corrected visual acuity (BSCVA), and 9% gained > or =2 Snellen lines. At the end of the study, 46% of eyes were within +/-1.0 D of the attempted corrected and 88% were within +/-3.0 D. There were 5 microkeratome-associated complications; 3 resulted in loss of BSCVA. The latest pachymetry showed a mean corneal thickness of 498.5 microm (range 396 to 552 microm). There were no cases of keratectasia. Seventy-five percent of patients noted an increase in their quality of life. Seventy-one percent were satisfied with their postoperative visual acuity; however, 75% noticed glare and halos at night. Laser in situ keratomileusis correction of very high myopia did not cause keratectasia in the long term provided the corneal thickness was respected. A flap thickness setting of 130 microm with a first-generation microkeratome resulted in a high number of cut failures. Most patients were happy with the results despite a modest level of accuracy and glare.Keywords
This publication has 11 references indexed in Scilit:
- Laser-assisted subepithelial keratectomy for the correction of myopiaJournal of Cataract & Refractive Surgery, 2002
- Corneal ectasia induced by laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2001
- Laser in situ keratomileusis with the VISX Star laser for myopia over −10.0 dioptersJournal of Cataract & Refractive Surgery, 2001
- Stability after laser in situ keratomileusis in moderately and extremely myopic eyesJournal of Cataract & Refractive Surgery, 2001
- The specific architecture of the anterior stroma accounts for maintenance of corneal curvatureBritish Journal of Ophthalmology, 2001
- Long-term results of laser in situ keratomileusis for high myopiaKorean Journal of Ophthalmology, 2000
- Complications of laser in situ keratomileusis for the correction of myopiaOphthalmology, 1999
- Laser in situ keratomileusis (LASIK) in myopia: 2-year resultsDer Ophthalmologe, 1998
- Photorefractive keratectomy: A 6-year follow-up studyOphthalmology, 1998
- A Corneal Flap Technique for Laser In Situ KeratomileusisAmerican Journal of Ophthalmology, 1991