American College of Radiology (ACR) and American Society for Radiation Oncology (ASTRO) Practice Guideline for Intensity-modulated Radiation Therapy (IMRT)
- 1 December 2012
- journal article
- practice guideline
- Published by Ovid Technologies (Wolters Kluwer Health) in American Journal of Clinical Oncology
- Vol. 35 (6), 612-617
- https://doi.org/10.1097/coc.0b013e31826e0515
Abstract
Intensity-modulated radiation therapy (IMRT) is a complex technique for the delivery of radiation therapy preferentially to target structures while minimizing doses to adjacent normal critical structures. It is widely utilized in the treatment of a variety of clinical indications in radiation oncology, including tumors of the central nervous system, head and neck, breast, prostate, gastrointestinal tract, and gynecologic organs, as well as in situations where previous radiation therapy has been delivered, and has allowed for significant therapeutic advances in many clinical areas. IMRT treatment planning and delivery is a complex process. Safe and reliable delivery of IMRT requires appropriate process design and adherence to quality assurance (QA) standards. A collaborative effort of the American College of Radiology and American Society for Therapeutic Radiation Oncology has produced a practice guideline for IMRT. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist, dosimetrist, and radiation therapist. Factors with respect to the QA of the treatment planning system, treatment-planning process, and treatment-delivery process are discussed, as are issues related to the utilization of volumetric modulated arc therapy. Patient-specific QA procedures are presented. Successful IMRT programs involve integration of many processes: patient selection, patient positioning/immobilization, target definition, treatment plan development, and accurate treatment delivery. Appropriate QA procedures, including patient-specific QA procedures, are essential to ensure quality in an IMRT program and to assure patient safety.Keywords
This publication has 24 references indexed in Scilit:
- American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) Practice Guideline for the Performance of Stereotactic Body Radiation TherapyInternational Journal of Radiation Oncology*Biology*Physics, 2010
- American Society of Radiation Oncology Recommendations for Documenting Intensity-Modulated Radiation Therapy TreatmentsInternational Journal of Radiation Oncology*Biology*Physics, 2009
- Volumetric Intensity-Modulated Arc Therapy Vs. Conventional IMRT in Head-and-Neck Cancer: A Comparative Planning and Dosimetric StudyInternational Journal of Radiation Oncology*Biology*Physics, 2009
- American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) Practice Guidelines for Intensity-Modulated Radiation Therapy (IMRT)International Journal of Radiation Oncology*Biology*Physics, 2009
- Commissioning and Quality Assurance of RapidArc Radiotherapy Delivery SystemInternational Journal of Radiation Oncology*Biology*Physics, 2008
- Intensity-Modulated Radiation Therapy: Supportive Data for Prostate CancerSeminars in Radiation Oncology, 2008
- Intensity-Modulated Radiotherapy in the Standard Management of Head and Neck Cancer: Promises and PitfallsJournal of Clinical Oncology, 2006
- Quality Assurance in Radiation OncologyJournal of the American College of Radiology, 2005
- Compensators: An alternative IMRT delivery techniqueJournal of Applied Clinical Medical Physics, 2004