Treatment of Unstable Distal Radial Fractures with the Volar Locking Plating System
- 1 December 2006
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in The Journal of Bone & Joint Surgery
- Vol. 88 (12), 2687-2694
- https://doi.org/10.2106/jbjs.e.01298
Abstract
Background: The best treatment for an inadequately reduced fracture of the distal part of the radius is not well established. We collected prospective outcomes data for patients undergoing open reduction and internal fixation of an inadequately reduced distal radial fracture with use of the volar locking plating system. Methods: Over a two-year period, 161 patients underwent open reduction and internal fixation of an inadequately reduced distal radial fracture with use of the volar locking plating system. Patients were enrolled in the present study three months after the fracture on the basis of strict entry criteria and were evaluated three, six, and twelve months after surgery. Outcome measures included radiographic parameters, grip strength, lateral pinch strength, the Jebsen-Taylor test, wrist range of motion, and the Michigan Hand Outcomes Questionnaire. Results: Eighty-seven patients with a distal radial fracture were enrolled. The mean age at the time of enrollment was 48.9 years. Forty percent (thirty-five) of the eighty-seven fractures were classified as AO type A, 9% (eight) were classified as type B, and 51% (forty-four) were classified as type C. Radiographic assessment showed that the plating system maintained anatomic reduction at the follow-up periods. At the time of the twelve-month follow-up, the mean grip strength on the injured side was worse than that on the contralateral side (18 compared with 21 kg; p < 0.01), the mean pinch strength on the injured side was not significantly different from that on the contralateral side (8.7 compared with 8.9 kg; p = 0.27), and the mean flexion of the wrist on the injured side was 86% of that on the contralateral side. All Michigan Hand Outcomes Questionnaire domains approached normal scores at six months, with small continued improvement to one year. Conclusions: The volar locking plating system appears to provide effective fixation when used for the treatment of initially inadequately reduced distal radial fractures. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.Keywords
This publication has 30 references indexed in Scilit:
- Responsiveness of the Michigan Hand Outcomes Questionnaire and the Disabilities of the Arm, Shoulder and Hand questionnaire in carpal tunnel surgeryThe Journal of Hand Surgery, 2005
- Clinical outcomes of carpal tunnel release in patients 65 and olderThe Journal of Hand Surgery, 2005
- Providing care for hand disorders a re-appraisal of needJournal of Hand Surgery (European Volume), 2004
- Carpal Tunnel Syndrome and WorkJournal of Hand Surgery (European Volume), 2004
- A prospective outcomes study of Swanson Metacarpophalangeal Joint Arthroplasty for the rheumatoid handThe Journal of Hand Surgery, 2004
- Treating Forearm Fractures Using an Internal FixatorPublished by Ovid Technologies (Wolters Kluwer Health) ,2001
- Reliability and validity testing of the Michigan Hand Outcomes QuestionnaireThe Journal of Hand Surgery, 1998
- Prospective multicenter trial of a plate for dorsal fixation of distal radius fracturesThe Journal of Hand Surgery, 1997
- Transmetacarpal Replantation of the Right Hand onto the LeftJournal of Hand Surgery (European Volume), 1991
- FrontispieceJournal of Hand Surgery (European Volume), 1990