Monte Carlo calculation of beam quality correction factors in proton beams using detailed simulation of ionization chambers
Open Access
- 4 March 2016
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (6), 2389-2406
- https://doi.org/10.1088/0031-9155/61/6/2389
Abstract
This work calculates beam quality correction factors (kQ) in monoenergetic proton beams using detailed Monte Carlo simulation of ionization chambers. It uses the Monte Carlo code penh and the electronic stopping powers resulting from the adoption of two different sets of mean excitation energy values for water and graphite: (i) the currently ICRU 37 and ICRU 49 recommended Iw = 75 eV and Ig = 78 eV and (ii) the recently proposed Iw = 78 eV and Ig = 81.1 eV. Twelve different ionization chambers were studied. The k Q factors calculated using the two different sets of I-values were found to agree with each other within 1.6% or better. k Q factors calculated using current ICRU I-values were found to agree within 2.3% or better with the k Q factors tabulated in IAEA TRS-398, and within 1% or better with experimental values published in the literature. k Q factors calculated using the new I-values were also found to agree within 1.1% or better with the experimental values. This work concludes that perturbation correction factors in proton beams--currently assumed to be equal to unity--are in fact significantly different from unity for some of the ionization chambers studied.Keywords
Funding Information
- Generalitat de Catalunya (2014 SGR 846)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina
- Ministerio de Economía y Competitividad (FIS2012-38480)
This publication has 41 references indexed in Scilit:
- Electron beam qualitykQ,Q0factors for various ionization chambers: a Monte Carlo investigation with penelopePhysics in Medicine & Biology, 2014
- Use of the BIPM calorimetric and ionometric standards in megavoltage photon beams to determineWairandIcPhysics in Medicine & Biology, 2014
- Gamos: A framework to do Geant4 simulations in different physics fields with an user-friendly interfaceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Consistency in reference radiotherapy dosimetry: resolution of an apparent conundrum when60Co is the reference quality for charged-particle and photon beamsPhysics in Medicine & Biology, 2013
- Geant4 and Fano cavity test: where are we?Journal of Physics: Conference Series, 2008
- The FLUKA code: description and benchmarkingAIP Conference Proceedings, 2007
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matterNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995
- Absorbed dose beam quality factors for the dosimetry of high-energy photon beamsPhysics in Medicine & Biology, 1992
- The design of a thimble chamber for the Farmer dosemeterPhysics in Medicine & Biology, 1972