Lower Dose of rhBMP-2 Achieves Spine Fusion When Combined With an Osteoconductive Bulking Agent in Non-human Primates
- 1 May 2005
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Spine
- Vol. 30 (10), 1127-1133
- https://doi.org/10.1097/01.brs.0000162623.48058.8c
Abstract
A non-human primate lumbar intertransverse process arthrodesis model was used to evaluate the effectiveness of different formulations of recombinant human bone morphogenetic protein-2 (rhBMP-2) to induce consistent bone formation. To determine if the combination of rhBMP-2/absorbable collagen sponge (ACS) wrapped around a bulking agent, consisting of a biphasic calcium phosphate/collagen composite, could achieve posterolateral spine fusion with a dose of rhBMP-2 (3.0 mg/side) that previously failed to induce posterolateral fusion in rhesus monkeys with other carriers. Successful bone induction in both human and non-human primates has required higher concentrations of BMP than were required in lower order models. The Food and Drug Administration approved concentration of rhBMP-2 for interbody fusion (1.5 mg/mL) when delivered on the ACS alone without a bulking agent (doses 3–9 mg/side) has failed to induce clinically relevant amounts of bone formation in a posterolateral spine fusion model in rhesus monkeys. Previously, a higher concentration of 2.0 mg/mL of rhBMP-2 delivered on stacked sheets of a biphasic calcium phosphate ceramic/collagen compression resistant matrix (CRM) was required to achieve fusion in the rhesus monkey and was the basis for this study (doses of 6–12 mg/side). Nine skeletally mature, rhesus macaque monkeys underwent single level posterolateral arthrodesis at L4–L5. Two different rhBMP-2 doses were evaluated in 3 delivery configurations. The first 3 monkeys received 10 mg/side (2.5 mL at 4.0 mg/mL) of rhBMP-2 loadeddirectly onto a CRM carrier (15% hydroxyapatite/85%β-tricalcium phosphate ceramic/collagen matrix), resulting in a final concentration of 2.0 mg/mL. The second 3monkeys received 3 mg/side (2.0 mL at 1.5 mg/mL) of rhBMP-2 loaded directly on the CRM carrier, resulting in a 0.6 mg/mL final concentration. Three additional monkeys also received the 3 mg/side (2.0 mL at 1.5 mg/mL) of rhBMP-2 delivered on an ACS, which was then wrapped around the dry CRM matrix used as a bulking agent, yielding a 1.5 mg/mL final concentration of rhBMP-2 on the sponge wrapped around the bulking agent. The monkeys were euthanized at 24 weeks after surgery. Manual palpation, plain radiographs, computerized tomography, and nondecalcified histology were used to evaluate fusion in a blinded fashion. The 3 monkeys with 10 mg rhBMP-2 placed directly on the CRM carrier (2.0 mg/mL final concentration) achieved solid fusion. The 3 monkeys that underwent fusion with 3 mg of rhBMP-2 placed directly on the CRM carrier (0.6 mg/mL final concentration) failed to achieve fusion. In contrast, the 3 monkeys that underwent fusion with the same 3 mg dose of rhBMP-2 dispensed only on an ACS that was wrapped around the CRM achieved solid bilateral fusion. This study shows the importance of carrier optimization and final implant protein concentration for the successful delivery of rhBMP-2. By combining the properties of the ACS with the CRM, the required dosage of rhBMP-2 was diminished by more than 3-fold in the non-human primate model. This finding suggests that the currently available concentration of rhBMP-2 (1.5 mg/mL) could be successful for achieving posterolateral spine fusion when combined with an osteoconductive bulking agent that can support the induced new bone formation.Keywords
This publication has 23 references indexed in Scilit:
- Lumbar Posterolateral Fusion Alone or With Transpedicular Instrumentation in L4–L5 Degenerative SpondylolisthesisJournal of SPINAL DISORDERS, 2001
- Minimum 5-Year Results of Degenerative Spondylolisthesis Treated With Decompression and Instrumented Posterior FusionSpine, 1999
- Patient Outcomes After Decompression and Instrumented Posterior Spinal Fusion for Degenerative SpondylolisthesisSpine, 1999
- A Randomized Prospective Study of Posterolateral Lumbar FusionSpine, 1999
- 1997 Volvo Award Winner in Clinical StudiesSpine, 1997
- Single-Level Posterolateral Arthrodesis, with or without Posterior Decompression, for the Treatment of Isthmic Spondylolisthesis in Adults. A Prospective, Randomized Study*The Journal of Bone & Joint Surgery, 1997
- Complications of Iliac Crest Bone Graft HarvestingClinical Orthopaedics and Related Research, 1996
- Iliac Crest Bone Graft Harvest Donor Site MorbiditySpine, 1995
- The Role of Fusion and Instrumentation in the Treatment of Degenerative Spondylolisthesis with Spinal StenosisJournal of SPINAL DISORDERS, 1993
- The Use of Primary Internal Fixation in SpondylolisthesisSpine, 1993