Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT)
- 20 November 2007
- journal article
- research article
- Published by Springer Science and Business Media LLC in Surgical Endoscopy
- Vol. 22 (6), 1464-1469
- https://doi.org/10.1007/s00464-007-9650-9
Abstract
Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers’ pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. The ACE device produced the highest temperatures (195.9° ± 14.5°C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4° ± 4.1°C, and PT = 87° ± 2.2°C). The LV and PT consistently yielded temperatures that were < 100°C independent of type of tissue or “on”/ “off” mode. Conversely, the ACE reached temperatures higher than 200°C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5°C) that could harm adjacent tissue or the surgeon’s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.Keywords
This publication has 19 references indexed in Scilit:
- Comparison of Monopolar Electrocoagulation, Bipolar Electrocoagulation, Ultracision, and LigasureSurgery Today, 2006
- PlasmaKinetic Bipolar Vessel Sealing: Burst Pressures and Thermal Spread in an Animal ModelJournal of Endourology, 2005
- A Comparison of Laparoscopic Bipolar Vessel Sealing Devices in the Hemostasis of Small-, Medium-, and Large-Sized ArteriesJournal of Laparoendoscopic & Advanced Surgical Techniques, 2003
- How Safe is High-Power Ultrasonic Dissection?Annals of Surgery, 2003
- Evaluation of a Vessel Sealing System, Bipolar Electrosurgery, Harmonic Scalpel, Titanium Clips, Endoscopic Gastrointestinal Anastomosis Vascular Staples and Sutures for Arterial and Venous Ligation in a Porcine ModelJournal of Urology, 2003
- Ultracision in gynaecological laparoscopic surgeryJournal of Obstetrics and Gynaecology, 2003
- Gross and histologic characteristics of laparoscopic injuries with four different energy sourcesFertility and Sterility, 2001
- High-burst-strength, feedback-controlled bipolar vessel sealingSurgical Endoscopy, 1998
- The harmonic scalpel: An intraoperative complicationObstetrics & Gynecology, 1996
- A Comparative Study of the Tissue-destroying Effect of the Laser and ElectrocoagulationEndoscopy, 1989