Spherical Aberration Correction in Tandem with Exit-Plane Wave Function Reconstruction: Interlocking Tools for the Atomic Scale Imaging of Lattice Defects in GaAs
- 17 March 2004
- journal article
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 10 (02), 185-198
- https://doi.org/10.1017/s1431927604040395
Abstract
With the availability of resolution boosting and delocalization minimizing techniques, for example, spherical aberration correction and exit-plane wave function reconstruction, high-resolution transmission electron microscopy is drawing to a breakthrough with respect to the atomic-scale imaging of common semiconductor materials. In the present study, we apply a combination of these two state-of-the-art techniques to investigate lattice defects in GaAs-based heterostructures at atomic resolution. Focusing on the direct imaging of stacking faults as well as the core structure of edge and partial dislocations, the practical capabilities of both techniques are illustrated. For the first time, we apply the technique of bright-atom contrast imaging at negative spherical aberration together with an appropriate overfocus setting for the investigation of lattice defects in a semiconductor material. For these purposes, the elastic displacements associated with lattice defects in GaAs viewed along the [110] zone axis are measured from experimental images using reciprocal space strain map algorithms. Moreover, we demonstrate the benefits of the retrieval of the exit-plane wave function not only for the elimination of residual imaging artefacts but also for the proper on-line alignment of specimens during operation of the electron microscope—a basic prerequisite to obtain a fair agreement between simulated images and experimental micrographs.Keywords
This publication has 21 references indexed in Scilit:
- High-Resolution Transmission Electron Microscopy Using Negative Spherical AberrationMicroscopy and Microanalysis, 2004
- Atomic-Resolution Imaging of Oxygen in Perovskite CeramicsScience, 2003
- Residual wave aberrations in the first spherical aberration corrected transmission electron microscopeUltramicroscopy, 1998
- Why don't high‐resolution simulations and images match?Journal of Microscopy, 1998
- Numerical correction of lens aberrations in phase-retrieval HRTEMUltramicroscopy, 1996
- The HREM use of the FEGTEM for the study of interfacesUltramicroscopy, 1995
- Atomic core structure of Lomer dislocation at GaAs/(001)Si interfacePhilosophical Magazine A, 1995
- Optimum focus for taking electron hologramsUltramicroscopy, 1991
- Core structure of the Lomer dislocation in germanium and siliconPhilosophical Magazine A, 1982
- Coma-free alignment of high resolution electron microscopes with the aid of optical diffractogramsUltramicroscopy, 1978