Effects of Heart Rate on Motion Artifacts of the Aorta on Non-ECG-Assisted 0.5-Sec Thoracic MDCT
- 1 April 2005
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 184 (4), 1225-1230
- https://doi.org/10.2214/ajr.184.4.01841225
Abstract
OBJECTIVE. Our aim was to evaluate the effects of heart rate on aortic motion artifacts on 0.5-sec non-ECG-assisted thoracic MDCT. MATERIALS AND METHODS. A total of 124 non-ECG-assisted thoracic MDCT scans with satisfactory simultaneous ECG data were reviewed. Scans were grouped according to patient heart rates (beats per minute [bpm]: group A, 46-55; B, 56-65; C, 66-75; D, 76-85; E, 86-95; and F > 95). The groups were compared regarding the presence, locations, and spatial distributions of pulsation artifact, number of slices affected, maximum amplitude of pulsation, continuity of artifact, and the presence of superior vena cava (SVC) pseudoflaps. RESULTS. Of the 124 scans, 114 (91.9%) had aortic motion artifacts, with prevalence ranging from 85.3% (66-75 bpm) to 100% (65 bpm or less). Of the 114 motion artifacts, all affected the ascending aorta, 105 (92.1%) involved the left anterior and right posterior aspects of the aortic circumference, and 106 (93%) were associated with SVC pseudoflaps. Group B had significantly greater numbers of images with artifacts (p < 0.001-0.006), greater artifact amplitudes (p < 0.001-0.002), and a higher continuity trend for the artifacts (p = 0.003-0.194) than did the other five groups. CONCLUSION. Aortic motion artifacts are frequently seen on thoracic MDCT, especially in patients with heart rates of 65 bpm or less. The presence of a SVC pseudoflap is helpful for distinguishing artifacts from dissection. If aortic disease is suspected, then measures to reduce motion artifact, such as ECG-gating, should be considered.Keywords
This publication has 15 references indexed in Scilit:
- Thoracic Aorta at Multi–Detector Row CT: Motion Artifact with Various Reconstruction WindowsRadiology, 2003
- Thoracic Aorta: Motion Artifact Reduction with Retrospective and Prospective Electrocardiography-assisted Multi–Detector Row CTRadiology, 2002
- Multislice helical CT: image temporal resolutionIEEE Transactions on Medical Imaging, 2000
- Pitfalls in the Diagnosis of Thoracic Aortic Dissection at CT AngiographyRadioGraphics, 2000
- System performance of multislice spiral computed tomographyIEEE Engineering in Medicine and Biology Magazine, 2000
- Subsecond multi-slice computed tomography: basics and applicationsEuropean Journal of Radiology, 1999
- Motion Artifacts of the Aorta Simulating Aortic Dissection on Spiral CTJournal of Computer Assisted Tomography, 1999
- Aortic MotionJournal of Computer Assisted Tomography, 1995
- Acute aortic dissection: typical and atypical imaging features.RadioGraphics, 1994
- Motion artifact simulating aortic dissection on CT.American Journal of Roentgenology, 1991