Red blood cell fatigue evaluation based on the close-encountering point between extensibility and recoverability
- 9 January 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (6), 1135-1141
- https://doi.org/10.1039/c3lc51003d
Abstract
Red blood cells (RBC) circulate the human body several hundred thousand times in their life span. Therefore, their deformability is really important, especially when they pass through a local capillary whose diameter can be as narrow as 3 μm. While there have been a number of works discussing the deformability in a simulated capillary such as a microchannel, as far as we examined in the literature, no work focusing on the change of shape after reciprocated mechanical stress has been reported so far. One of the reasons is that there have been no appropriate experimental systems to achieve such a test. This paper presents a new concept of RBC fatigue evaluation. The fatigue state is defined by the time of reciprocated mechanical stress when the extensibility and the recoverability characteristics meet each other. Our challenge is how to construct a system capable of achieving stable and accurate control of RBCs in a microchannel. For this purpose, we newly introduced two fundamental components. One is a robotic pump capable of manipulating a cell in the accuracy of ±0.24 μm in an equilibrium state with a maximum response time of 15 ms. The other is an online high speed camera capable of chasing the position of RBCs with a sampling rate of 1 kHz. By utilizing these components, we could achieve continuous observation of the length of a RBC over a 1000 times reciprocated mechanical stress. Through these experiments, we found that the repeat number that results in the fatigue state has a close correlation with extensibility.Keywords
This publication has 16 references indexed in Scilit:
- Biomechanics approaches to studying human diseasesTrends in Biotechnology, 2007
- Deformation and nano-rheology of red blood cells: An AFM investigationColloids and Surfaces B: Biointerfaces, 2006
- Association of reduced red blood cell deformability and diabetic nephropathyKidney International, 2005
- Mechanics of the human red blood cell deformed by optical tweezersJournal of the Mechanics and Physics of Solids, 2003
- Optical tweezers for measuring red blood cell elasticity: application to the study of drug response in sickle cell diseaseEuropean Journal of Haematology, 2003
- Contribution of parasite proteins to altered mechanical properties of malaria-infected red blood cellsBlood, 2002
- Direct Measurement of Erythrocyte Deformability in Diabetes Mellitus with a Transparent Microchannel Capillary Model and High-Speed Video Camera SystemMicrovascular Research, 2001
- Abnormal Blood Flow and Red Blood Cell Deformability in Severe MalariaParasitology Today, 2000
- Red Blood Cell Deformability in SepsisAmerican Journal of Respiratory and Critical Care Medicine, 1998
- The Incidence of Decreased Red Blood Cell Deformability in Sepsis and the Association With Oxygen Free Radical Damage and Multiple-System Organ FailureArchives of Surgery, 1989