Improving sensitivity in micro‐free flow electrophoresis using signal averaging
- 20 April 2009
- journal article
- microfluidics and-miniaturization
- Published by Wiley in Electrophoresis
- Vol. 30 (8), 1342-1348
- https://doi.org/10.1002/elps.200800497
Abstract
Microfluidic free‐flow electrophoresis (μFFE) is a separation technique that separates continuous streams of analytes as they travel through an electric field in a planar flow channel. The continuous nature of the μFFE separation suggests that approaches more commonly applied in spectroscopy and imaging may be effective in improving sensitivity. The current paper describes the S /N improvements that can be achieved by simply averaging multiple images of a μFFE separation; 20–24‐fold improvements in S /N were observed by averaging the signal from 500 images recorded for over 2 min. Up to an 80‐fold improvement in S /N was observed by averaging 6500 images. Detection limits as low as 14 pM were achieved for fluorescein, which is impressive considering the non‐ideal optical set‐up used in these experiments. The limitation to this signal averaging approach was the stability of the μFFE separation. At separation times longer than 20 min bubbles began to form at the electrodes, which disrupted the flow profile through the device, giving rise to erratic peak positions.Keywords
This publication has 39 references indexed in Scilit:
- Fast Electrophoretic Separation Optimization Using Gradient Micro Free-Flow ElectrophoresisAnalytical Chemistry, 2008
- Microfluidic High-Resolution Free-Flow Isoelectric FocusingAnalytical Chemistry, 2007
- Electrostatic induction of the electric field into free-flow electrophoresis devicesLab on a Chip, 2006
- Free flow electrophoresis coupled with liquid chromatography–mass spectrometry for a proteomic study of the human cell line (K562/CR3)Journal of Chromatography A, 2004
- Direct chemiluminescent imaging detection of serum proteins in polyacrylamide gelsAnalytica Chimica Acta, 2003
- Lowering the UV absorbance detection limit and increasing the sensitivity of capillary electrophoresis using a dual linear photodiode array detector and signal averagingJournal of Microcolumn Separations, 1999
- Free flow electrophoresis for the purification of proteins: I. Zone electrophoresis and isotachophoresisElectrophoresis, 1990
- Characterization of artifical liposomes with free-flow electrophoresisElectrophoresis, 1990
- Scale‐up of free‐flow electrophoresis: II. Purification of alcohol dehydrogenase from a crude yeast extract by field step electrophoresis and combined field step‐zone electrophoresisElectrophoresis, 1990
- Scale‐up of free flow electrophoresis: I. Purification of alcohol dehydrogenase from a crude yeast extract by zone electrophoresisElectrophoresis, 1990