Commentary: Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial

Abstract
A commentary on Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial by The INFANT Collaborative Group (2017). Lancet 389, 1719–1729. doi: 10.1016/S0140-6736(17)30568-8 The recent study by the INFANT group reported no evidence of benefit on neonatal outcomes associated with the use of decision-support software in conjunction with cardiotocography (CTG) compared with CTG alone (The INFANT Collaborative Group, 2017). Concerns about the study design have been voiced (Keith, 2017). Earlier studies comparing continuous CTG with intermittent auscultation during labor have shown CTG during labor to be associated with reduced rates of neonatal seizures, largely of unknown long term consequence, but no clear differences in other measures of neonatal mortality and morbidity. However, continuous CTG is associated with increased operative delivery rates (Alfirevic et al., 2017). We now know that supplementing CTG with decision-support software is unlikely to improve outcomes. Yet, given the absence of any alternative to CTG, for high risk women, it is likely that conventional CTG will retain a firm grip in labor wards. Efforts should now be directed toward interrogating fetal heart rate variability (fHRV) more deeply and/or measuring and evaluating different physiological parameters of intrapartum fetal well-being. For example, the true predictive ability of fetal ECG can only be determined once it is collected at a sampling rate that preserves more of the underlying physiological information. We have demonstrated this approach to assess the severity of hypoxic ischaemic encephalopathy (HIE) in the immediate newborn period (Goulding et al., 2017). Animal and human studies show that the current mode of ECG acquisition is outdated, imprecise, and discards important predictive information (Durosier et al., 2014; Li et al., 2015). To address this challenge, we recently developed and validated an algorithm for low-cost, portable high quality maternal, and fetal ECG monitoring capable of working with one or two maternal abdominal ECG channels to extract the fetal ECG (Li and Wu, 2017; Wu et al., 2017). While we need at least two channels for the algorithm introduced in (Wu et al., 2017), it could be applied to handle the single channel maternal abdominal ECG signal as generalized in (Li and Wu, 2017). An important challenge is refining the algorithm to perform well in the case of twin pregnancies. Also, for the wide acceptance of the technology, it will have to be considerably less expensive than the currently available fetal ECG monitors. Surprisingly little research has been done on what is perhaps the most obvious and direct source of predictive information about fetal brain health, the Electroencephalogram (EEG), even though it is very sensitive to hypoxia-ischaemia (Murray et al., 2016; Finn et al., 2017). Using animal models, we have developed and validated a new algorithm for fetal EEG as predictor of academia (Frasch et al., 2015) and are beginning a clinical study using a fetal EEG prototype device (NCT03013569). Our data shows that pathognomonic EEG changes emerge at a pH ≤ 7.20, which the INFANT study reported in at least 12% of all babies. We expect that direct acquisition of fetal EEG during labor and a more precise acquisition of fetal ECG (and fHRV) offers potential in preventing acidosis and brain injury due to intrapartum hypoxia-ischaemia. Fetal infection is an important contributor to perinatal brain injury and fHRV has been shown to reflect fetal inflammatory response systematically and in an organ-specific manner (Durosier et al., 2015; Frasch et al., 2016; Liu et al., 2016). Prospective studies in large ante- and intrapartum cohorts of pregnant women and fetuses are now needed to validate the utility of fetal ECG and EEG monitors. Such studies will not only yield biomarkers to predict complications during delivery due to underlying infection, hypoxia or acidemia, but also pinpoint the risks for abnormal postnatal developmental trajectories. Knowing on which babies to focus will provide a foundation upon which to build the therapeutic strategies to correct early deviations from healthy developmental trajectories. All authors listed have made a substantial, direct and intellectual contribution to the work, and approved it for publication. MF acknowledges support by CIHR and FRQS. HW is partially supported by Sloan Research Fellow FR-2015-65363. MF is an inventor of related patent application entitled “EEG Monitor of Fetal Health” including U.S. Patent 9,215,999. MF and HW filed a patent for the aECG method referred to in this commentary. The other authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. Alfirevic, Z., Devane, D., Gyte, G. M., and Cuthbert, A. (2017). Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst. Rev. 2:CD006066. doi: 10.1002/14651858.CD006066 PubMed Abstract | CrossRef Full Text | Google Scholar Durosier, L. D., Green, G., Batkin, I., Seely, A. J., Ross, M. G., Richardson, B. S., et al. (2014). Sampling rate of heart rate variability impacts the ability to detect acidemia in ovine fetuses near-term. Front. Pediatr. 2:38. doi: 10.3389/fped.2014.00038 PubMed Abstract | CrossRef Full Text | Google Scholar Durosier, L. D., Herry, C., Cortes, M., Cao, M., Burns, P., Desrochers, A., et al. (2015). Does heart rate variability reflect the systemic inflammatory response in a fetal sheep model of lipopolysaccharide-induced sepsis? Physiol. Meas. 36, 2089–2102. doi: 10.1088/0967-3334/36/10/2089 PubMed Abstract | CrossRef Full Text | Google Scholar Finn, D., Dempsey, E. M., and Boylan, G. B. (2017). Lost in transition: a systematic review of neonatal electroencephalography in the delivery room—are we forgetting an important biomarker for newborn brain health? Front. Pediatr. 5:173. doi: 10.3389/fped.2017.00173 PubMed Abstract | CrossRef Full Text | Google Scholar Frasch, M. G., Durosier, L. D., Gold, N., Cao, M., Matushewski, B., Keenliside, L., et al. (2015). Adaptive shut-down of EEG activity predicts critical acidemia in the near-term ovine fetus. Physiol. Rep. 3:e12435. doi: 10.14814/phy2.12435 PubMed Abstract | CrossRef Full Text | Google Scholar Frasch, M. G., Szynkaruk, M., Prout, A. P., Nygard, K., Cao, M., Veldhuizen, R., et al. (2016). Decreased neuroinflammation correlates to higher vagus nerve activity fluctuations in near-term ovine fetuses: a case for the afferent cholinergic anti-inflammatory pathway? J. Neuroinflammation 13:103. doi: 10.1186/s12974-016-0567-x PubMed Abstract | CrossRef Full Text | Google Scholar Goulding, R. M., Stevenson, N. J., Murray, D. M., Livingstone, V., Filan, P. M., and Boylan, G. B. (2017). Heart rate variability in hypoxic ischemic encephalopathy during therapeutic hypothermia. Pediatr. Res. 81, 609–615. doi: 10.1038/pr.2016.245 PubMed Abstract | CrossRef Full Text | Google Scholar Keith, R. (2017). The INFANT study-a flawed design foreseen. Lancet 389, 1697–1698. doi: 10.1016/S0140-6736(17)30714-6 PubMed Abstract | CrossRef Full Text | Google Scholar Li, S., and Wu, H.-T. (2017). Extract fetal ECG from single-lead abdominal ECG by de-shape short time Fourier transform and nonlocal median. Front. Appl. Math. Stat. 3:2. doi: 10.3389/fams.2017.00002 CrossRef Full Text | Google Scholar Li, X., Xu, Y., Herry, C., Durosier, L. D., Casati, D., Stampalija, T., et al. (2015). Sampling frequency of fetal heart rate impacts the ability to predict pH and BE at birth: a retrospective multi-cohort study. Physiol. Meas. 36, L1–L12. doi: 10.1088/0967-3334/36/5/L1 PubMed Abstract | CrossRef Full Text | Google Scholar Liu, H. L., Garzoni, L., Herry, C., Durosier, L. D., Cao, M., Burns, P., et al. (2016). Can monitoring fetal intestinal inflammation using heart rate variability analysis signal incipient necrotizing enterocolitis of the neonate? Pediatr. Crit. Care Med. 17, e165–e176. doi: 10.1097/PCC.0000000000000643 PubMed Abstract | CrossRef Full Text | Google Scholar Murray, D. M., O'Connor, C. M., Ryan, C. A., Korotchikova, I., and Boylan, G. B. (2016). Early EEG grade and outcome at 5 years after mild neonatal hypoxic ischemic encephalopathy. Pediatrics 138. doi: 10.1542/peds.2016-0659 PubMed Abstract | CrossRef Full Text | Google Scholar The INFANT Collaborative Group (2017). Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial. Lancet 389, 1719–1729. doi: 10.1016/S0140-6736(17)30568-8 PubMed Abstract | CrossRef Full Text Wu, H. T., Li, R., and Frasch, M. G. (2017). Efficient fetal-maternal ECG signal separation from two channel maternal abdominal ECG via diffusion-based channel selection. Front. Physiol. 8:277. doi: 10.3389/fphys.2017.00277 PubMed Abstract | CrossRef Full Text | Google Scholar Keywords: labor, fHRV, EEG, acidemia, sampling rate, FHR, neonate Citation: Frasch MG, Boylan GB, Wu H and Devane D (2017) Commentary: Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial Front. Physiol. 8:721. doi: 10.3389/fphys.2017.00721 Received: 07 July 2017; Accepted: 06 September 2017; Published: 28 September 2017. Edited by: Reviewed by: Copyright © 2017 Frasch, Boylan, Wu and Devane. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. *Correspondence: Martin G. Frasch, mfrasch@uw.edu
Funding Information
  • Canadian Institutes of Health Research
  • Fonds de Recherche du Québec - Santé
  • Alfred P. Sloan Foundation (FR-2015-65363)

This publication has 16 references indexed in Scilit: