Dynamics of teat-end vacuum during machine milking: types, causes and impacts on teat condition and udder health – a literature review
Open Access
- 5 May 2015
- journal article
- review article
- Published by Informa UK Limited in Journal of Applied Animal Research
- Vol. 44 (1), 263-272
- https://doi.org/10.1080/09712119.2015.1031780
Abstract
Most of the available scientific literature concerning claw vacuum drops and fluctuations (identical to teat-end vacuum) during machine milking has been published in the 1960s and 1970s. Fewer studies have been carried out more recently on modern types of dairy cows, and milking machines, and have been evaluated with modern statistical methods and software. Based on the accessible information, there are indications that reduced milking performance, leading to long machine-on time mainly as a consequence of a combination of vacuum drops and different types of fluctuations, may influence udder health in a negative way although scientific proofs are scarce. Based on an ISO note, the claw vacuum should remain within a range of 32–42 kPa during peak milk flow to ensure fast, complete and gentle milking. This range of vacuum pressure allows adequate liner movement and a sufficient pressure on the teat during the massage (d-) phase is guaranteed. Thus, liner slips caused by too low claw vacuum are avoided. On the other hand, the teat-end vacuum should not be much higher than 42 kPa as it can cause damage of teat tissue mainly during periods of low milk flow when it is almost identical with the system vacuum. Depending on the used system of milk transport through the tubes, the teat-end vacuum drops to some extent, intensified during periods of high milk flow and reduced during periods of low or absent milk flow at the start and end of milking. Hence, a general increase of system vacuum throughout milking is not suitable, as high teat-end vacuum acting on the teat during milking phases with low milk flow rates have to be avoided. However, a reduction of machine-on time and high vacuum load on the teat during low milk flow can potentially be achieved by early cluster removal, before complete cessation of milk flow. Ideally, this goal can be reached at quarter milking (as used in automatic milking systems) where each teatcup is individually removed based on the milk flow of the individual teat, and milking at very low or no milk flow can easily be avoided.Keywords
This publication has 37 references indexed in Scilit:
- Milk flow-dependent vacuum loss in high-line milking systems: Effects on milking characteristics and teat tissue conditionJournal of Dairy Science, 2010
- Interactions of vacuum, b-phase duration, and liner compression on milk flow rates in dairy cowsJournal of Dairy Science, 2009
- Milk flow-controlled changes of pulsation ratio and pulsation rate affect milking characteristics in dairy cowsJournal of Dairy Research, 2009
- Continuously elevated concentrations of oxytocin during milking are necessary for complete milk removal in dairy cowsJournal of Dairy Research, 1994
- Influence of Pulsationless Milking on Teat Canal Keratin and MastitisJournal of Dairy Science, 1994
- Increased Susceptibility to lntramammary Infection Following Removal of Teat Canal KeratinJournal of Dairy Science, 1992
- Effect of Milking Without Pulsation on Teat Duct Colonization with Streptococcus agalactiae and Penetrability to EndotoxinJournal of Dairy Science, 1991
- Measurement of machine-induced changes in thickness of the bovine teatJournal of Dairy Research, 1990
- Further short-term studies of the influence of the milking machine on the rate of new mastitis infectionsJournal of Dairy Research, 1973
- 415. Factors affecting the rate of machine milkingJournal of Dairy Research, 1950