Hepatic perfusion in a tumor model using DCE-CT: an accuracy and precision study
- 24 July 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (16), 4249-4267
- https://doi.org/10.1088/0031-9155/53/16/003
Abstract
In the current study we investigate the accuracy and precision of hepatic perfusion measurements based on the Johnson and Wilson model with the adiabatic approximation. VX2 carcinoma cells were implanted into the livers of New Zealand white rabbits. Simultaneous dynamic contrast-enhanced computed tomography (DCE-CT) and radiolabeled microsphere studies were performed under steady-state normo-, hyper- and hypo-capnia. The hepatic arterial blood flows (H(A)BF) obtained using both techniques were compared with ANOVA. The precision was assessed by the coefficient of variation (CV). Under normo-capnia the microsphere H(A)BF were 51.9 +/- 4.2, 40.7 +/- 4.9 and 99.7 +/- 6.0 ml min(-1) (100 g)(-1) while DCE-CT H(A)BF were 50.0 +/- 5.7, 37.1 +/- 4.5 and 99.8 +/- 6.8 ml min(-1) (100 g)(-1) in normal tissue, tumor core and rim, respectively. There were no significant differences between H(A)BF measurements obtained with both techniques (P > 0.05). Furthermore, a strong correlation was observed between H(A)BF values from both techniques: slope of 0.92 +/- 0.05, intercept of 4.62 +/- 2.69 ml min(-1) (100 g)(-1) and R(2) = 0.81 +/- 0.05 (P < 0.05). The Bland-Altman plot comparing DCE-CT and microsphere H(A)BF measurements gives a mean difference of -0.13 ml min(-1) (100 g)(-1), which is not significantly different from zero. DCE-CT H(A)BF is precise, with CV of 5.7, 24.9 and 1.4% in the normal tissue, tumor core and rim, respectively. Non-invasive measurement of H(A)BF with DCE-CT is accurate and precise. DCE-CT can be an important extension of CT to assess hepatic function besides morphology in liver diseases.Keywords
This publication has 46 references indexed in Scilit:
- The prediction of radiation‐induced liver dysfunction using a local dose and regional venous perfusion modelMedical Physics, 2007
- Early Changes in Liver Perfusion Caused by Occult Metastases in Rats: Detection with Quantitative CTRadiology, 2001
- Statistical Methodology for the Concurrent Assessment of Interrater and Intrarater Reliability: Using Goniometric Measurements as an ExamplePTJ: Physical Therapy & Rehabilitation Journal, 1994
- Microvascular permeability of normal and neoplastic tissuesMicrovascular Research, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Liver Circulation and Function during Isoflurane and Halothane AnesthesiaAnesthesiology, 1984
- Flow Estimation by Indicator Dilution (Bolus Injection)Circulation Research, 1970
- The Permeability of Capillaries in Various Organs as Determined by Use of the ‘Indicator Diffusion’ MethodActa Physiologica Scandinavica, 1963
- A linear method for determining liver sinusoidal and extravascular volumesAmerican Journal of Physiology-Legacy Content, 1963
- Effect of Anesthesia and Hepatic Sampling Site Upon Hepatic Blood FlowAmerican Journal of Physiology-Legacy Content, 1958