To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III (10.73 ± 0.96 MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth (4.17 ± 1.11 MPa) (p < 0.001). Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth.Keywords
This publication has 14 references indexed in Scilit:
- A comparative investigation into relative bond strengths of Damon3, Damon3MX, and APC II brackets using different primer and adhesive combinations.European Journal of Orthodontics, 2011
- Plant Extract Ankaferd Blood Stopper Effect on Bond StrengthAngle Orthodontist, 2010
- Effects of adhesion promoters on the shear bond strengths of orthodontic brackets to fluorosed enamelEuropean Journal of Orthodontics, 2008
- A New Premixed Self-Etch Adhesive for Bonding Orthodontic BracketsAngle Orthodontist, 2008
- Effect of self-etchant pH on the shear bond strength of orthodontic bracketsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- Influence of different tooth types on the bond strength of two orthodontic adhesive systemsEuropean Journal of Orthodontics, 2008
- Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesiveAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Effect of blood and saliva contamination on shear bond strength of brackets bonded with 4 adhesivesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primerAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003