Evaluation of ammonia measurements in dogs with two analysers for use in veterinary practice
- 8 May 1999
- journal article
- research article
- Published by Wiley in Veterinary Record
- Vol. 144 (19), 523-526
- https://doi.org/10.1136/vr.144.19.523
Abstract
The measurement of ammonia in biological fluids is the only way to diagnose and evaluate hepatic encephalopathy, but samples for ammonia measurement cannot be stored or sent by post. Two analysers for use in veterinary practice have recently become available, the VetTest and the Blood Ammonia Checker II; the reliability of ammonia measurements in canine blood with these two analysers has been evaluated by comparing the results with a standard automated enzymatic assay. Blood samples from 39 dogs, with a range of ammonia concentrations from 5 to 589 microM, were used simultaneously in the three assays. The blood samples were placed immediately on ice, and the measurements were made in duplicate. The intra-assay coefficients of variation were 13.7 per cent for the VetTest, 4.7 per cent for the Blood Ammonia Checker, and 2.8 per cent for the enzymatic assay. The correlation coefficients over the entire range of concentrations were 0.79 between the VetTest and the enzymatic assay, and 0.98 between the Ammonia Checker and the enzymatic assay. The ammonia concentrations recorded in the enzymatic assay were divided into 12 samples within the normal range (0 to 50 microM), 18 samples with moderately increased concentrations (51 to 150 microM), and nine samples with concentrations above 150 microM. No correlation or a poor correlation was found between the results from the VetTest and those from the enzymatic assay from 0 to 50 microM (R = 0.27) and from 50 to 150 microM (R = 0.51; P = 0.05). The results from the VetTest were only reliable in samples with the highest concentrations (R = 0.93; P < 0.05). In contrast, the results from the Ammonia Checker correlated well with the results from the enzymatic assay over all the ranges: R = 0.79 (P < 0.05) from 0 to 50 microM, R = 0.86 (P < 0.05) from 50 to 150 microM, and R = 1.00 (P < 0.05) in samples exceeding 150 microM.Keywords
This publication has 16 references indexed in Scilit:
- The Pituitary-Adrenocortical System in Canine Hepato-EncephalopathyPublished by S. Karger AG ,2015
- Circulatory disorders of the liver in dogs and catsVeterinary Quarterly, 1995
- Increasing incidence of hereditary intrahepatic portosystemic shunts in Irish wolfhounds in The Netherlands (1984 to 1992)Veterinary Record, 1995
- Hepatic EncephalopathyJournal of Veterinary Internal Medicine, 1992
- A rapid method for blood ammonia determination using the new blood ammonia checker (BAC) IIClinica Chimica Acta; International Journal of Clinical Chemistry, 1992
- Variations in Total Bile Acid Concentration in Serum of Dogs after a Test MealJournal of Veterinary Medicine Series A, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Feline Hepatic DiseaseVeterinary Clinics of North America: Small Animal Practice, 1984
- Influences of specimen processing and storage conditions on results for plasma ammonia.Clinical Chemistry, 1984
- Blood ammoniaBiochemical Journal, 1939