Abstract
Background Microplate-based thrombin generation test (TGT) is widely used as clinical measure of global hemostatic potential and it becomes a useful tool for control of drug potency and quality by drug manufactures. However, the convenience of the microtiter plate technology can be deceiving: microplate assays are prone to location-based variability in different parts of the microtiter plate. Methods In this report, we evaluated the well-to-well consistency of the TGT variant specifically applied to the quantitative detection of the thrombogenic substances in the immune globulin product. We also studied the utility of previously described microplate layout designs in the TGT experiment. Results Location of the sample on the microplate (location effect) contributes to the variability of TGT measurements. Use of manual pipetting techniques and applications of the TGT to the evaluation of procoagulant enzymatic substances are especially sensitive. The effects were not sensitive to temperature or choice of microplate reader. Smallest location effects were observed with automated dispenser-based calibrated thrombogram instrument. Even for an automated instrument, the use of calibration curve resulted in up to 30% bias in thrombogenic potency assignment. Conclusions Use of symmetrical version of the strip-plot layout was demonstrated to help to minimize location artifacts even under the worst-case conditions. Strip-plot layouts are required for quantitative thrombin-generation based bioassays used in the biotechnological field.Keywords
This publication has 19 references indexed in Scilit:
- Data Mining of the Public Version of the FDA Adverse Event Reporting SystemInternational Journal of Medical Sciences, 2013
- Fluorogenic Peptide‐Based Substrates for Monitoring Thrombin ActivityChemMedChem, 2012
- Zymogen-like factor Xa variants restore thrombin generation and effectively bypass the intrinsic pathway in vitroBlood, 2011
- Thrombin generation is extremely sensitive to preheating conditionsJournal of Thrombosis and Haemostasis, 2011
- Prospective assessment of thrombin generation test for dose monitoring of bypassing therapy in hemophilia patients with inhibitors undergoing elective surgeryBlood, 2010
- Thrombin Generation Testing for Monitoring Hemophilia Treatment: A Clinical PerspectiveSeminars in Thrombosis and Hemostasis, 2010
- Potency and mass of factor VIII in FVIII productsHaemophilia, 2009
- Initiation and propagation of coagulation from tissue factor‐bearing cell monolayers to plasma: initiator cells do not regulate spatial growth rateJournal of Thrombosis and Haemostasis, 2005
- Studies on the Different Modes of Action of the Anticoagulant Protease Inhibitors DX-9065a and Argatroban: I. EFFECTS ON THROMBIN GENERATIONOnline Journal of Public Health Informatics, 2002
- A Thrombin Generation Test: The Application in Haemophilia and ThrombocytopeniaJournal of Clinical Pathology, 1953