Abstract
Deep brain stimulation (DBS) provides dramatic tremor relief when delivered at high-stimulation frequencies (more than ∼100 Hz), but its mechanisms of action are not well-understood. Previous studies indicate that high-frequency stimulation is less effective when the stimulation train is temporally irregular. The purpose of this study was to determine the specific characteristics of temporally irregular stimulus trains that reduce their effectiveness: long pauses, bursts, or irregularity per se. We isolated these characteristics in stimulus trains and conducted intraoperative measurements of postural tremor in eight volunteers. Tremor varied significantly across stimulus conditions ( P < 0.015), and stimulus trains with pauses were significantly less effective than stimulus trains without ( P < 0.002). There were no significant differences in tremor between trains with or without bursts or between trains that were irregular or periodic. Thus the decreased effectiveness of temporally irregular DBS trains is due to long pauses in the stimulus trains, not the degree of temporal irregularity alone. We also conducted computer simulations of neuronal responses to the experimental stimulus trains using a biophysical model of the thalamic network. Trains that suppressed tremor in volunteers also suppressed fluctuations in thalamic transmembrane potential at the frequency associated with cerebellar burst-driver inputs. Clinical and computational findings indicate that DBS suppresses tremor by masking burst-driver inputs to the thalamus and that pauses in stimulation prevent such masking. Although stimulation of other anatomic targets may provide tremor suppression, we propose that the most relevant neuronal targets for effective tremor suppression are the afferent cerebellar fibers that terminate in the thalamus.Keywords
This publication has 83 references indexed in Scilit:
- Individual Fiber Anatomy of the Subthalamic Region Revealed With Diffusion Tensor Imaging: A Concept to Identify the Deep Brain Stimulation Target for Tremor SuppressionNeurosurgery, 2011
- Deep Brain Stimulation Alleviates Parkinsonian Bradykinesia by Regularizing Pallidal ActivityJournal of Neurophysiology, 2010
- Deep Brain Stimulation Reduces Neuronal Entropy in the MPTP-Primate Model of Parkinson's DiseaseJournal of Neurophysiology, 2008
- Probability distributions of the logarithm of inter-spike intervals yield accurate entropy estimates from small datasetsJournal of Neuroscience Methods, 2008
- Tremor varies as a function of the temporal regularity of deep brain stimulationNeuroReport, 2008
- Mechanisms of Deep Brain Stimulation in Movement Disorders as Revealed by Changes in Stimulus FrequencyNeurotherapeutics, 2008
- Pulse-to-Pulse Changes in the Frequency of Deep Brain Stimulation Affect Tremor and Modeled Neuronal ActivityJournal of Neurophysiology, 2007
- Unitary IPSPs Drive Precise Thalamic Spiking in a Circuit Required for LearningNeuron, 2005
- Propofol–contrasting effects in movement disordersBritish Journal of Neurosurgery, 1994
- Rhythmic activity induced by harmaline in the olivo-cerebello-bulbar system of the catBrain Research, 1973