Abstract
Background —Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. Methods and Results —We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency transthoracic electrical field, which is applied via standard skin electrodes. We investigated localization accuracy within the right atrium, right ventricle, and left ventricle by comparing measured and true interelectrode distances of a decapolar catheter. Long-term stability was analyzed by localization of the most proximal His bundle before and after slow pathway ablation. Electrogram recordings were unaffected by the applied electrical field. Localization data from 3 catheter positions, widely distributed within the right atrium, right ventricle, or left ventricle, were analyzed in 10 patients per group. The relationship between measured and true electrode positions was highly linear, with an average correlation coefficient of 0.996, 0.997, and 0.999 for the right atrium, right ventricle, and left ventricle, respectively. Localization accuracy was better than 2 mm, with an additional scaling error of 8% to 14%. After 2 hours, localization of the proximal His bundle was reproducible within 1.4±1.1 mm. Conclusions —This new technique enables accurate and reproducible real-time localization of electrode positions in cardiac mapping and ablation procedures. Its application does not distort the quality of electrograms and can be applied to any electrode catheter.Keywords
This publication has 15 references indexed in Scilit:
- Role of the Tricuspid Annulus and the Eustachian Valve/Ridge on Atrial FlutterCirculation, 1996
- Multipolar endocardial mapping of the right atrium during cardiac catheterization: description of a new techniqueJournal of the American College of Cardiology, 1993
- Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutterThe American Journal of Cardiology, 1993
- An anatomically guided approach to atrioventricular node slow pathway ablationThe American Journal of Cardiology, 1992
- Ablation of Ventricular Tachycardia Using Multiple Sequential Transcatheter Application of Radiofrequency EnergyPacing and Clinical Electrophysiology, 1992
- Treatment of Supraventricular Tachycardia Due to Atrioventricular Nodal Reentry by Radiofrequency Catheter Ablation of Slow-Pathway ConductionNew England Journal of Medicine, 1992
- High frequency alternating current ablation of an accessory pathway in humansJournal of the American College of Cardiology, 1987
- Transvenous Catheter Ablation of a Posteroseptal Accessory Pathway in a Patient with the Wolff–Parkinson–White SyndromeNew England Journal of Medicine, 1984
- Catheter Technique for Closed-Chest Ablation of an Accessory Atrioventricular PathwayNew England Journal of Medicine, 1983
- Role of catheter mapping in the preoperative evaluation of ventricular tachycardiaThe American Journal of Cardiology, 1982