Effect of phacoemulsification on facility of outflow
Open Access
- 13 April 2018
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 102 (11), 1520-1526
- https://doi.org/10.1136/bjophthalmol-2017-311548
Abstract
Purpose Phacoemulsification has been shown to reduce intraocular pressure (IOP). The mechanism of action is thought to be via increased trabecular outflow facility. However, studies on the relationship between phacoemulsification and outflow facility have been inconsistent. This study intended to examine the change in electronic Schiotz tonographic outflow facility (TOF) and IOP measurements following phacoemulsification. Methods Patients who were due to undergo a standard clear corneal incision phacoemulsification with intraocular lens (IOL) implantation, at St Thomas’ Hospital, were invited to participate in this study. IOP was measured using Goldmann’s applanation tonometer, and TOF was measured by electronic Schiotz tonography at baseline and at 3, 6 and 12 months postoperatively. Results Forty-one patients were recruited. Tonography data for 27 patients were reliable and available at all time points. Eleven cases had primary open angle glaucoma and cataract, while 16 patients had cataract only. Mean IOP reduced at every time point postoperatively significantly compared with baseline. TOF improved significantly after cataract extraction at all time points (baseline of 0.14±0.06 vs 0.18±0.09 at 3 months, P=0.02 and 0.20±0.09 at 6 months, P=0.003, 0.17±0.07 µL/min mmHg at 12 months, P=0.04). Five contralateral eyes of patients with cataracts only who did not have any intraocular surgery during the follow-up period were used as comparison. Their IOP and TOF did not change significantly at any postoperative visits. Conclusion This is the first study using electronic Schiotz tonography with documented anterior chamber depth and gonioscopy after modern cataract surgery (CS) with phacoemulsification and IOL implantation. We demonstrated that phacoemulsification increases TOF and this fully accounts for the IOP reduction following CS. ISTCRN registration number ISRCTN04247738.Keywords
This publication has 33 references indexed in Scilit:
- Preoperative Factors Associated with IOP Reduction After Cataract SurgeryOptometry and Vision Science, 2013
- Reduction in Intraocular Pressure after Cataract Extraction: The Ocular Hypertension Treatment StudyOphthalmology, 2012
- Randomized Evaluation of the Trabecular Micro-Bypass Stent with Phacoemulsification in Patients with Glaucoma and CataractOphthalmology, 2011
- The effect of cataract extraction on intraocular pressureCurrent Opinion in Opthalmology, 2010
- Mechanism of Action of Bimatoprost, Latanoprost, and Travoprost in Healthy Subjects: A Crossover StudyOphthalmology, 2008
- Three and Five Year Changes in Intraocular Pressures After Clear Corneal Phacoemulsification in Open Angle Glaucoma Patients, Glaucoma Suspects, and Normal PatientsJournal of Glaucoma, 2006
- Long-term intraocular pressure control after clear corneal phacoemulsification in glaucoma patientsJournal of Cataract & Refractive Surgery, 2005
- Ultrasound Activates the TM ELAM-1/IL-1/NF-κB Response: A Potential Mechanism for Intraocular Pressure Reduction after PhacoemulsificationInvestigative Ophthalmology & Visual Science, 2003
- Effect of cataract extraction and posterior chamber lens implantation on outflow facility and its response to pilocarpine in Korean subjectsBritish Journal of Ophthalmology, 2000
- The effect of cataract extraction with implant in glaucomatous eyesAustralian and New Zealand Journal of Ophthalmology, 1992