Abstract
Phase contrast (PC) magnetic resonance imaging with a three‐dimensional, radially undersampled acquisition allows for the acquisition of high resolution angiograms and velocimetry in dramatically reduced scan times. However, such an acquisition is sensitive to blurring and artifacts from off‐resonance and trajectory errors. A dual‐echo trajectory is proposed with a novel trajectory calibration from prescan data coupled with a multi‐frequency reconstruction to correct for these errors. Comparisons of phantom data and in vivo results from volunteer, and patients with arteriovenous malformations patients are presented with and without these corrections and show significant improvement of image quality when both corrections are applied. The results demonstrate significantly improved visualization of vessels, allowing for highly accelerated PC acquisitions without sacrifice in image quality. Magn Reson Med 60:1329–1336, 2008.Funding Information
- National Institutes of Health (1RO1-HL62465)
This publication has 27 references indexed in Scilit:
- Fat/water separation in single acquisition steady‐state free precession using multiple echo radial trajectoriesMagnetic Resonance in Medicine, 2005
- Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacementThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Time‐resolved three‐dimensional phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2003
- MRI measurement of time‐resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictionsJournal of Magnetic Resonance Imaging, 2003
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Magnetic resonance velocity imaging using a fast spiral phase contrast sequenceMagnetic Resonance in Medicine, 1994
- Minimizing TE in moment‐nulled or flow‐encoded two‐and three‐dimensional gradient‐echo imagingJournal of Magnetic Resonance Imaging, 1992
- Deblurring for non‐2D fourier transform magnetic resonance imagingMagnetic Resonance in Medicine, 1992
- Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiographyJournal of Magnetic Resonance Imaging, 1991
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991