Utility of millipore filter and cell block in thyroid needle aspirates: Which method is superior?
- 15 December 2006
- journal article
- Published by Wiley in Diagnostic Cytopathology
- Vol. 35 (1), 34-38
- https://doi.org/10.1002/dc.20571
Abstract
The main goal of thyroid fine‐needle aspiration (FNA) is to distinguish nodules that require surgery from those that do not, thereby decreasing the number of diagnostic thyroidectomies. Several cytologic preparations are used to reach a definitive diagnosis, including smears using conventional stains, such as Diff‐Quik (DQ) and Papanicolaou (Pap), millipore filters (MF), and cell blocks (CB). This study is undertaken to study the efficacy and adequacy to reach a definitive diagnosis of two cytologic preparations, MF and CB, in thyroid aspirates. All thyroid needle aspirates performed at Emory University Hospitals from January 2003 to April 2005 that had both MF and CB preparations for microscopic evaluation were studied. Conventional stains (DQ and Pap) were prepared. An initial aliquot of the specimen was divided for MF, and the remaining specimen submitted for CB preparation. All MF and CB slides were reviewed blindly. Adequacy criteria were assessed as 6–8 groups of follicular cells, with each containing 10 or more cells. Patient demographics, cytologic diagnoses, and follow‐up information were retrieved. A total of 218 cases met our criteria; 21 of these cases were excluded due to lack of available diagnostic slides. Thus, a total of 197 cases were studied. Approximately two‐third of the cases (57.9%) were diagnosed on DQ‐ and Pap‐stained smears only, in which both CB and MF were inadequate. About 4.6% of the cases were diagnostic on both CB and MF; 36.0% on MF only, and 1.5% on CB preparation only. In more than half the cases (57.9%), diagnosis of thyroid FNA was rendered only on conventional stained smears. MF smears appeared to be superior for diagnostic yield (40.6%) than CB (6.1%), which is dependent on specimen cellularity. Therefore, MF rather than CB should be added to conventional stained smears (DQ and Pap) to supplement the diagnostic yield, especially in specimens of low cellularity. Diagn. Cytopathol. 2007;35:34–38.Keywords
This publication has 11 references indexed in Scilit:
- Utility of cell blocks in the diagnosis of thyroid aspiratesDiagnostic Cytopathology, 2006
- Artifacts of cytology cell block in fine-needle aspiration biopsy of thyroidDiagnostic Cytopathology, 2004
- Assessment of Nondiagnostic Ultrasound-Guided Fine Needle Aspirations of Thyroid NodulesJournal of Clinical Endocrinology & Metabolism, 2002
- Evidence-Based Criteria for Adequacy in Thyroid Fine-Needle AspirationAmerican Journal of Clinical Pathology, 2002
- Accuracy of Thyroid Fine-Needle Aspiration Using Receiver Operator Characteristic CurvesAmerican Journal of Clinical Pathology, 2001
- Ultrasound-guided fine-needle aspiration biopsy of the thyroid: Role of on-site assessment and multiple cytologic preparationsDiagnostic Cytopathology, 2000
- Millipore Filter® Cell Block Preparation: An Alternative to Cell Block in Nongynecologic Specimens of Limited CellularityDiagnostic Cytopathology, 1999
- Fine-needle aspiration in the evaluation of thyroid neoplasmsEndocrine Pathology, 1997
- Diagnostic pitfalls in thyroid fine‐needle aspiration: A review of 394 casesDiagnostic Cytopathology, 1993
- A Comparison of the Cell Block, Papanicolaou, and Millipore Filter Technics for the Cytologic Examination of Serous FluidsAmerican Journal of Clinical Pathology, 1960