Multi–Detector Row CT Attenuation Measurements: Assessment of Intra- and Interscanner Variability with an Anthropomorphic Body CT Phantom
Top Cited Papers
- 1 January 2007
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 242 (1), 109-119
- https://doi.org/10.1148/radiol.2421052066
Abstract
Purpose: To determine the dependence of absolute computed tomographic (CT) attenuation values on multi–detector row CT scanner type, convolution kernel, and tube current by using an anthropomorphic phantom. Materials and Methods: A customized phantom was designed with tissue-equivalent materials to simulate contrast material–enhanced liver, spleen, pancreas, aorta, kidney, 0- and 50-HU cylindric renal cysts, muscle, and fat. The phantom was scanned with five multi–detector row CT scanners (LightSpeed QXi, GE Healthcare, Milwaukee, Wis; MX8000, Philips Medical Systems, Best, the Netherlands; and Volume Zoom, Sensation 16 and Sensation 64, Siemens Medical Solutions, Forchheim, Germany) on five separate occasions with 120 kVp, low and high tube current settings, 3.00–3.75-mm section thickness, 50% overlap, and standard and high-spatial-resolution kernels. Standardized regions of interest (ROIs) were used to obtain 3510 attenuation measurements. Attenuation dependence on scanner, kernel, and tube current was ...Keywords
This publication has 18 references indexed in Scilit:
- Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature.American Journal of Roentgenology, 1998
- Noninvasive measurements of bone mass, structure, and strength: current methods and experimental techniques.American Journal of Roentgenology, 1991
- Standardized Quantitative High Resolution CT in Lung DiseasesJournal of Computer Assisted Tomography, 1991
- The small (less than or equal to 3.0 cm) renal parenchymal tumor: detection, diagnosis, and controversies.Radiology, 1991
- The CT appearance of cystic masses of the liver.RadioGraphics, 1989
- The current radiological approach to renal cysts.Radiology, 1986
- Dependence of substance CT number on scanning technique and position within scannerComputerized Radiology, 1983
- Factors Influencing Quantitative CT Measurements of Solitary Pulmonary NodulesJournal of Computer Assisted Tomography, 1982
- The unreliability of CT numbers as absolute valuesAmerican Journal of Roentgenology, 1982
- CT of the solitary pulmonary noduleAmerican Journal of Roentgenology, 1980