Random process estimator for laser speckle imaging of cerebral blood flow
Open Access
- 23 December 2009
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (1), 218-236
- https://doi.org/10.1364/oe.18.000218
Abstract
In this paper, we develop a random process theory to explain the laser speckle phenomena. The relation between the probability distribution of speckle’s integrated intensity random process and the relative velocity is derived. Based on the random process theory, traditional spatial or temporal laser speckle contrast analysis (i.e. spatial or temporal LASCA) can be derived as the spatial or temporal estimators respectively. Both spatial LASCA and temporal LASCA suffer from noise due to insufficient statistics and nonstationarity in either spatial or temporal domain. Furthermore, either LASCA results in a reduction of spatial or temporal resolution. A new random process estimator is proposed and able to overcome these drawbacks. In an in-vitro study, random process estimator outperforms either spatial LASCA or temporal LASCA by providing much higher SNR (random process estimator vs. spatial LASCA vs. temporal LASCA: 33.64±6.87 () vs. 9.08±2.85 vs. 3.83±1.05). In an in-vivo structural imaging study, random process estimator efficiently suppresses the noise in contrast image and thus improves the distinguishability of small vessels. In a functional imaging study of cerebral blood flow change in the somatosensory cortex induced by rat’s hind paw stimulation, random process estimator provides much lower estimation errors in single trial data (random process estimator vs. temporal LASCA: 0.31±0.03 vs. 1.36±0.09) and finally leads to higher resolution spatiotemporal patterns of cerebral blood flow.
Keywords
This publication has 18 references indexed in Scilit:
- Speckle-visibility spectroscopy: A tool to study time-varying dynamicsReview of Scientific Instruments, 2005
- Heterogeneous response of cerebral blood flow to hypotension demonstrated by laser speckle imaging flowmetry in ratsNeuroscience Letters, 2004
- Spatiotemporal Quantification of Cerebral Blood Flow during Functional Activation in Rat Somatosensory Cortex using Laser-Speckle FlowmetryJournal of Cerebral Blood Flow & Metabolism, 2004
- Speckle Visibility Spectroscopy and Variable Granular FluidizationPhysical Review Letters, 2003
- Modified laser speckle imaging method with improved spatial resolutionJournal of Biomedical Optics, 2003
- Dynamic Imaging of Cerebral Blood Flow Using Laser SpeckleJournal of Cerebral Blood Flow & Metabolism, 2001
- Investigating non-Gaussian scattering processes by using nth -order intensity correlation functionsJournal of the Optical Society of America A, 1999
- Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlationJournal of the Optical Society of America A, 1997
- Diffusing wave spectroscopyPhysical Review Letters, 1988
- Flow visualization by means of single-exposure speckle photographyOptics Communications, 1981