Range of Motion and Lordosis of the Lumbar Spine
- 1 January 2001
- journal article
- diagnostics
- Published by Ovid Technologies (Wolters Kluwer Health) in Spine
- Vol. 26 (1), 53-60
- https://doi.org/10.1097/00007632-200101010-00011
Abstract
Study Design. Repeated measures for intratester reliability were performed. Objectives. To investigate the intratester reliability of a new measurement technique that evaluates lumbar range of motion in three planes using a pelvic restraint device, and to examine the reliability of lumbar lordosis measurement by inclinometer technique. Preliminary normative data on lumbar range of motion and lumbar lordosis were collected for comparison with the findings of previous studies. Summary of Background Data. Various noninvasive measurement methods have been developed for recording lumbar range of motion. However, pelvic movement was not effectively restricted during the use of these measurement techniques. The use of the pelvic restraint device to measure lumbar range of motion has not been investigated previously. Very few studies have investigated the reliability of quantifying lumbar lordosis by the inclinometer technique. Methods. Normative values were measured in 35 healthy men, and 12 of these subjects were included for the reliability study. Pelvic motion was limited by the pelvic restraint device during lumbar range of motion measurement in standing. An inclinometer was used for evaluation of lumbar flexion, extension, lateral flexion, and lumbar lordosis, whereas a lumbar rotameter was used to measure axial rotation. Results. Good intratester reliability was shown in the lumbar range of motion and lordosis measurement. Most of the intraclass correlation coefficient and Pearson’s r values (accompanied with nonsignificant paired t tests) were greater than 0.9, and most of the intrasubject coefficients of variation were less than 10%. The values of lumbar range of motion in three planes and lumbar lordosis found in the current study were comparable with those from most of the previous studies on these measurements in the normal population. Conclusions. Inclinometer and lumbar rotameter measurements with the use of a pelvic restraint device are reliable for measuring lumbar spine range of motion. Use of the inclinometer technique to record lumbar lordosis also is a reliable measure.Keywords
This publication has 46 references indexed in Scilit:
- Lumbar Range of Motion: Influence of Time of Day and Individual Factors on MeasurementsSpine, 1996
- Normal motion of the lumbar spine as related to age and genderEuropean Spine Journal, 1995
- Influence of Hamstring Length on the Standing Position and Flexion Range of Motion of the Pelvic Angle, Lumbar Angle, and Thoracic AngleJournal of Orthopaedic & Sports Physical Therapy, 1994
- Analysis of Spine Motion Variability Using a Computerized Goniometer Compared to Physical Examination A Prospective Clinical StudySpine, 1994
- Interexaminer Reliability and Discriminant Validity of Inclinometric Measurement of Lumbar Rotation in Chronic Low-Back Pain Patients and Subjects Without Low-Back PainSpine, 1992
- Motion of the Lumbar Spine Reliability of Two Measurement TechniquesSpine, 1991
- Bone Mineral Content, Gender, Body Posture, and Build in Relation to Back Pain in Middle AgeSpine, 1989
- Repeatability of Four Clinical Methods for Assessment of Lumbar Spinal MotionSpine, 1988
- An electronic inclinometer technique for measuring lumbar curvatureClinical Biomechanics, 1986
- Reliability and Validity of Four Instruments for Measuring Lumbar Spine and Pelvic PositionsPTJ: Physical Therapy & Rehabilitation Journal, 1986