High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation
- 1 July 2015
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 61 (7), 983-989
- https://doi.org/10.1373/clinchem.2014.231530
Abstract
BACKGROUND: Initial reports suggest that concentrations of high-sensitivity cardiac troponin T (hs-cTnT) (Roche Diagnostics Elecsys®) below the limit of blank (LoB) (3 ng/L) or limit of detection (LoD) (5 ng/L) of the assay have almost 100% negative predictive value (NPV) for acute myocardial infarction (AMI), particularly among patients without electrocardiograph (ECG) evidence of ischemia. We aimed to prospectively validate those findings. METHODS: We included adults presenting to the emergency department with suspected cardiac chest pain. Standard troponin T (cTnT) and hs-cTnT (both Roche Elecsys) were tested in samples drawn on arrival. The primary outcome was AMI, adjudicated by 2 investigators on the basis of clinical data and ≥12-h cTnT testing. We also evaluated diagnostic performance when AMI was readjudicated on the basis of hs-cTnT (≥12-h) concentrations. RESULTS: Of 463 patients included, 79 (17.1%) had AMI. Twenty-four patients (5.2%) had hs-cTnT concentrations below the LoB, although none had AMI. Ninety-six patients (20.7%) had hs-cTnT concentrations below the LoD, 1 of whom had AMI. Thus, diagnostic sensitivity was 98.7% (95% CI 87.5%–98.6%) and NPV was 99.0% (95% CI 94.3%–100.0%). Of the 17.3% (n = 80) patients with hs-cTnT below the LoD and no ECG ischemia, none had AMI. Thus, diagnostic sensitivity was 100.0% (95% CI 95.4%–100.0%) and NPV was 100.0% (95% CI 95.5%–100.0%). Sensitivity and NPV were maintained when AMI was readjudicated on the basis of hs-cTnT. CONCLUSIONS: Our findings confirm that patients with nonischemic ECG and undetectable hs-cTnT at presentation have a very low probability of AMI, although the proportion of patients affected was smaller than in previous research.Keywords
Funding Information
- College of Emergency Medicine
- Roche
- National Institute for Health Research
- Siemens
- Alere
This publication has 15 references indexed in Scilit:
- Undetectable High-Sensitivity Cardiac Troponin T Level in the Emergency Department and Risk of Myocardial InfarctionJournal of the American College of Cardiology, 2014
- Small Changes in Troponin T Levels Are Common in Patients With Non–ST-Segment Elevation Myocardial Infarction and Are Linked to Higher MortalityJournal of the American College of Cardiology, 2013
- Preparing the United States for High-Sensitivity Cardiac Troponin AssaysJournal of the American College of Cardiology, 2013
- Clinical Implications of a Recent Adjustment to the High-Sensitivity Cardiac Troponin T Assay: User BewareClinical Chemistry, 2012
- Analytical Characteristics of High-Sensitivity Cardiac Troponin AssaysClinical Chemistry, 2012
- Effect of freeze–thaw and refrigeration conditions on high-sensitivity troponin T concentrationsAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2011
- Rapid Exclusion of Acute Myocardial Infarction in Patients With Undetectable Troponin Using a High-Sensitivity AssayJournal of the American College of Cardiology, 2011
- Short- and Long-Term Risk Stratification Using a Next-Generation, High-Sensitivity Research Cardiac Troponin I (hs-cTnI) Assay in an Emergency Department Chest Pain PopulationClinical Chemistry, 2009
- Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin AssaysThe New England Journal of Medicine, 2009
- Long-Term Health Outcomes Associated with Detectable Troponin I ConcentrationsClinical Chemistry, 2007