Transepidermal water loss in young and aged healthy humans: a systematic review and meta-analysis
- 23 January 2013
- journal article
- review article
- Published by Springer Science and Business Media LLC in Archiv für dermatologische Forschung
- Vol. 305 (4), 315-323
- https://doi.org/10.1007/s00403-012-1313-6
Abstract
Transepidermal water loss (TEWL) is regarded as one of the most important parameters for characterizing skin barrier function but an agreed upon definition of what a “normal” TEWL is does not exist. In order to determine generalizable TEWL values for healthy adults, a systematic review and meta-analysis was conducted. The databases MEDLINE and EMBASE and publication lists were screened. After full-text appraisal of 398 studies, 231 studies were excluded due to unclear or insufficient reporting. 167 studies providing data about 50 skin areas were included in the final data synthesis. Pooled sample sizes ranged from n = 5 for the left cheek and the left lower back to a maximum of n = 2,838 for the right midvolar forearm area. The lowest TEWL of 2.3 (95 % CI 1.9–2.7) g/m2/h was calculated for the breast skin, the highest TEWL of 44.0 (39.8–48.2) g/m2/h for the axilla. TEWL in individuals being 65 years and above was consistently lower compared to the group of 18- to 64-year-old individuals. The quality of reporting TEWL in humans should be increased in future studies.Keywords
This publication has 45 references indexed in Scilit:
- Variation of Biophysical Parameters of the Skin with Age, Gender, and Body RegionThe Scientific World Journal, 2012
- Irritability of the skin barrier: A comparison of chronologically aged and photo-aged skin in elderly and young adultsEuropean Geriatric Medicine, 2011
- Side‐by‐side comparison of an open‐chamber (TM 300) and a closed‐chamber (Vapometer™) transepidermal water loss meterSkin Research and Technology, 2011
- Strengthening the Reporting of Observational Studies in Epidemiology (STROBE): Explanation and ElaborationPLoS Medicine, 2007
- The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement: Guidelines for Reporting Observational StudiesPLoS Medicine, 2007
- Validation of the VapoMeter, a closed unventilated chamber system to assess transepidermal water loss vs. the open chamber Tewameter®Skin Research and Technology, 2005
- Percutaneous absorption and inflammation in aged skin: A reviewJournal of the American Academy of Dermatology, 1994
- Age-related changes in the elastic properties and thickness of human facial skinBritish Journal of Dermatology, 1994
- Meta-analysis in clinical trialsControlled Clinical Trials, 1986