Performance of Two Advanced Rainwater Harvesting Systems in Washington DC

Abstract
Combined sewer overflows (CSOs) are a concern for many cities managing stormwater through combined sewer systems, including the District of Columbia (DC). Advanced rainwater harvesting (ARH) is an innovative approach to managing stormwater and has the potential to minimize CSOs and maximize water conservation. ARH systems use continuous monitoring and adaptive control (CMAC) technology to store or release water from a rainwater harvesting cistern. This study assessed the efficacy of ARH systems to mitigate wet weather discharges at two firehouses in DC. Continuous monitoring data was collected over a period of three years for the systems that were installed in 2012. The collected data indicates that the systems were effective at mitigating wet weather discharges, with average event harvesting rates greater than 95%. These results suggest that if implemented on a larger scale, ARH systems would be a valuable tool in effectively managing stormwater.