Molecular and Microscopic Analysis of Bacteria and Viruses in Exhaled Breath Collected Using a Simple Impaction and Condensing Method
Open Access
- 25 July 2012
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (7), e41137
- https://doi.org/10.1371/journal.pone.0041137
Abstract
Exhaled breath condensate (EBC) is increasingly being used as a non-invasive method for disease diagnosis and environmental exposure assessment. By using hydrophobic surface, ice, and droplet scavenging, a simple impaction and condensing based collection method is reported here. Human subjects were recruited to exhale toward the device for 1, 2, 3, and 4 min. The exhaled breath quickly formed into tiny droplets on the hydrophobic surface, which were subsequently scavenged into a 10 µL rolling deionized water droplet. The collected EBC was further analyzed using culturing, DNA stain, Scanning Electron Microscope (SEM), polymerase chain reaction (PCR) and colorimetry (VITEK 2) for bacteria and viruses. Experimental data revealed that bacteria and viruses in EBC can be rapidly collected using the method developed here, with an observed efficiency of 100 µL EBC within 1 min. Culturing, DNA stain, SEM, and qPCR methods all detected high bacterial concentrations up to 7000 CFU/m3 in exhaled breath, including both viable and dead cells of various types. Sphingomonas paucimobilis and Kocuria variants were found dominant in EBC samples using VITEK 2 system. SEM images revealed that most bacteria in exhaled breath are detected in the size range of 0.5–1.0 µm, which is able to enable them to remain airborne for a longer time, thus presenting a risk for airborne transmission of potential diseases. Using qPCR, influenza A H3N2 viruses were also detected in one EBC sample. Different from other devices restricted solely to condensation, the developed method can be easily achieved both by impaction and condensation in a laboratory and could impact current practice of EBC collection. Nonetheless, the reported work is a proof-of-concept demonstration, and its performance in non-invasive disease diagnosis such as bacterimia and virus infections needs to be further validated including effects of its influencing matrix.Keywords
This publication has 46 references indexed in Scilit:
- Size‐resolved emission rates of airborne bacteria and fungi in an occupied classroomIndoor Air, 2012
- Exhaled breath condensate pH as a biomarker of COPD severity in ex-smokersRespiratory Research, 2011
- The great challenge for exhaled breath analysis: embracing complexity, delivering simplicityJournal of Breath Research, 2011
- Exhaled breath condensate sampling is not a new method for detection of respiratory virusesVirology Journal, 2011
- Concentrations and size distributions of airborne influenza A viruses measured indoors at a health centre, a day-care centre and on aeroplanesJournal of The Royal Society Interface, 2011
- Measurements of Airborne Influenza Virus in Aerosol Particles from Human CoughsPLOS ONE, 2010
- Detection of VirulentRhodococcus equiin Exhaled Air Samples from Naturally Infected FoalsJournal of Clinical Microbiology, 2009
- An optimized method to detect influenza virus and human rhinovirus from exhaled breath and the airborne environmentJournal of Environmental Monitoring, 2008
- Influenza Virus in Human Exhaled Breath: An Observational StudyPLOS ONE, 2008
- Proteomics as a Method for Early Detection of Cancer: A Review of Proteomics, Exhaled Breath Condensate, and Lung Cancer ScreeningJournal of General Internal Medicine, 2007