Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses
Top Cited Papers
- 1 February 2012
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 262 (2), 435-449
- https://doi.org/10.1148/radiol.11110640
Abstract
Purpose: To determine whether adding shear-wave (SW) elastographic features could improve accuracy of ultrasonographic (US) assessment of breast masses. Materials and Methods: From September 2008 to September 2010, 958 women consented to repeat standard breast US supplemented by quantitative SW elastographic examination in this prospective multicenter institutional review board-approved, HIPAA-compliant protocol. B-mode Breast Imaging Reporting and Data System (BI-RADS) features and assessments were recorded. SW elastographic evaluation (mean, maximum, and minimum elasticity of stiffest portion of mass and surrounding tissue; lesion-to-fat elasticity ratio; ratio of SW elastographic-to-B-mode lesion diameter or area; SW elastographic lesion shape and homogeneity) was performed. Qualitative color SW elastographic stiffness was assessed independently. Nine hundred thirty-nine masses were analyzable; 102 BI-RADS category 2 masses were assumed to be benign; reference standard was available for 837 category 3 or higher lesions. Considering BI-RADS category 4a or higher as test positive for malignancy, effect of SW elastographic features on area under the receiver operating characteristic curve (AUC), sensitivity, and specificity after reclassifying category 3 and 4a masses was determined. Results: Median participant age was 50 years; 289 of 939 (30.8%) masses were malignant (median mass size, 12 mm). B-mode BI-RADS AUC was 0.950; eight of 303 (2.6%) BI-RADS category 3 masses, 18 of 193 (9.3%) category 4a lesions, 41 of 97 (42%) category 4b lesions, 42 of 57 (74%) category 4c lesions, and 180 of 187 (96.3%) category 5 lesions were malignant. By using visual color stiffness to selectively upgrade category 3 and lack of stiffness to downgrade category 4a masses, specificity improved from 61.1% (397 of 650) to 78.5% (510 of 650) (P < .001); AUC increased to 0.962 (P = .005). Oval shape on SW elastographic images and quantitative maximum elasticity of 80 kPa (5.2 m/sec) or less improved specificity (69.4% [451 of 650] and 77.4% [503 of 650], P < .001 for both), without significant improvement in sensitivity or AUC. Conclusion: Adding SW elastographic features to BI-RADS feature analysis improved specificity of breast US mass assessment without loss of sensitivity.Keywords
This publication has 31 references indexed in Scilit:
- Cystic Breast Masses and the ACRIN 6666 ExperienceRadiologic Clinics of North America, 2010
- Short-Term Follow-Up of Palpable Breast Lesions With Benign Imaging Features: Evaluation of 375 Lesions in 320 WomenAmerican Journal of Roentgenology, 2009
- Complicated Breast Cysts on Sonography: Is Aspiration Necessary to Exclude Malignancy?Academic Radiology, 2008
- Clinical Application of the BI-RADS Final Assessment to Breast Sonography in Conjunction with MammographyAmerican Journal of Roentgenology, 2008
- Imaging and Estimation of Tissue Elasticity by UltrasoundUltrasound Quarterly, 2007
- Revisiting the Mammographic Follow-Up of BI-RADS Category 3 LesionsAmerican Journal of Roentgenology, 2002
- IMAGING OF BREAST MASSESRadiologic Clinics of North America, 2000
- Sonography of palpable breast cancerJournal of Clinical Ultrasound, 2000
- Incidental findings on sonography of the breast: clinical significance and diagnostic workup.American Journal of Roentgenology, 1999