Intracranial navigation by using low-field intraoperative magnetic resonance imaging: preliminary experience
- 1 November 2002
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 97 (5), 1115-1124
- https://doi.org/10.3171/jns.2002.97.5.1115
Abstract
Intracranial navigation by using intraoperative magnetic resonance (iMR) imaging allows the surgeon to reassess anatomical relationships in near-real time during brain tumor surgery. The authors report their initial experience with a novel neuronavigation system coupled to a low-field iMR imaging system. Between October 2000 and December 2001, 70 neurosurgical procedures were performed using the mobile 0.12-tesla PoleStar N-10 iMR imaging system. The cases included 38 craniotomies, 15 brain biopsies, nine transsphenoidal approaches, and one drainage of a subdural hematoma. Tumor resection was performed using the awake method in seven of 38 cases. Of the craniotomies, image-confirmed complete or radical tumor resection was achieved in 28 cases, subtotal resection in eight cases, and open biopsies in two cases. Tumor resection was controlled with the use of image guidance until the final intraoperative images demonstrated that there was no residual tumor or that no critical brain tissue was at risk of compromise. In each stereotactic biopsy the location of the biopsy needle could be verified by intraoperative imaging and diagnostic tissue was obtained. Complications included a case of aseptic meningitis after a biopsy and one case of temporary intraoperative failure of the anesthesia machine. Awake craniotomies were performed successfully with no permanent neurological complications. Intraoperative MR image-based neuronavigation is feasible when using the Odin PoleStar N-10 system for tumor resections that require multiple other surgical adjuncts including awake procedures, cortical mapping, monitoring of somatosensory evoked potentials, or electrocorticography. Use of the system for brain biopsies offers the opportunity of immediate verification of the needle tip location. Standard neurosurgical drills, microscopes, and other equipment can be used safely in conjunction with this iMR imaging system.Keywords
This publication has 42 references indexed in Scilit:
- Novel, Compact, Intraoperative Magnetic Resonance Imaging-guided System for Conventional Neurosurgical Operating RoomsNeurosurgery, 2001
- Glioma Resection in a Shared-resource Magnetic Resonance Operating Room after Optimal Image-guided Frameless Stereotactic ResectionNeurosurgery, 2001
- Quantification of, Visualization of, and Compensation for Brain Shift Using Intraoperative Magnetic Resonance ImagingNeurosurgery, 2000
- Advances in Mobile Intraoperative Magnetic Resonance ImagingNeurosurgery, 2000
- Brain Tumor Surgery with the Toronto Open Magnetic Resonance Imaging System: Preliminary Results for 36 Patients and Analysis of Advantages, Disadvantages, and Future ProspectsNeurosurgery, 2000
- Frameless stereotaxy with scalp-applied fiducial markers for brain biopsy procedures: experience in 218 casesJournal of Neurosurgery, 1999
- The Present and Future Role of Intraoperative MRI in Neurosurgical ProceduresStereotactic and Functional Neurosurgery, 1997
- Characterization of Spatial Distortion in Magnetic Resonance Imaging and Its Implications for Stereotactic SurgeryNeurosurgery, 1994
- Three-dimensional digitizer (neuronavigator): New equipment for computed tomography-guided stereotaxic surgerySurgical Neurology, 1987