Analysis of surface whitening of extracted hydrophobic acrylic intraocular lenses
- 1 November 2009
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Cataract & Refractive Surgery
- Vol. 35 (11), 1927-1934
- https://doi.org/10.1016/j.jcrs.2009.07.004
Abstract
To identify the cause of light scattering on the surface (ie, whitening) of extracted AcrySof intraocular lenses (IOLs). Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan. Dislocated IOLs extracted from 3 patients were stored and the IOL surfaces examined under light microscopy. The effect of whitening on visual function was evaluated by measuring light transmission with a spectrophotometer. To determine the cause of opacification, the IOLs were examined for calcium phosphate deposits using an electron probe X-ray microanalyzer. The IOL surface, including the presence of organic deposits and evidence of hydrolysis, was also examined by Fourier-transform infrared spectrophotometry. The IOLs were then dried, immersed again in physiological saline, and serially examined for changes in opacification. The optic surfaces of all IOLs had opacification due to whitening. Light transmission in the visible range of 360 to 800 nm was 4% less than that of unused IOLs. The X-ray microanalysis showed no calcium phosphate deposits. Fourier-transform infrared spectrophotometry of the IOL optic material showed no evidence of hydrolysis. Opacification disappeared after the IOLs were dried and then reappeared over time when the IOL was immersed again in physiologic saline. The findings strongly suggest that whitening of the hydrophobic acrylic IOL was due to trace water molecules that infiltrate the optic. Within the 3-dimensional network of the polymeric lens material, the molecules are too small to form observable voids but can form water aggregates of sufficient size to scatter visible light, causing opacification (ie, whitening).Keywords
This publication has 18 references indexed in Scilit:
- Comparison of anterior capsule contraction between 5 foldable intraocular lens modelsJournal of Cataract & Refractive Surgery, 2008
- Preventing secondary cataract and anterior capsule contraction by modification of intraocular lensesExpert Review of Medical Devices, 2008
- Equilibrium water content and glistenings in acrylic intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- Surface scattering in implanted hydrophobic intraocular lensesJournal of Cataract & Refractive Surgery, 2003
- Clinical and Experimental Observation of Glistening in Acrylic Intraocular LensesJapanese Journal of Ophthalmology, 2001
- Glistening formation in an AcrySof lens initiated by spinodal decompositionof the polymer network bytemperature changeJournal of Cataract & Refractive Surgery, 2001
- Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyesJournal of Cataract & Refractive Surgery, 2000
- Relationship between intraocular lens biomaterials and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1998
- Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: Randomized comparison of the cellular reaction on the anterior lens surfaceJournal of Cataract & Refractive Surgery, 1998
- Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySofJournal of Cataract & Refractive Surgery, 1997