Of the 400,000–500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved over a 5-year period (1989–1993). This article analyzes results from January 1994 through April 1996, a period during which techniques were fairly stable. Extraction of 3,540 leads from 2,338 patients was attempted at 226 centers. Indications were: infection (27%), nonfunctional or incompatible leads (25%), Accufix® or Encor® leads (46%), or other causes (2%). Patients were 64 ± 17 years of age (range 5–96); 59% were men, 41% women. Leads were implanted 47 ± 41 months (maximum 26 years), in the atrium (53%), ventricle (46%), or SVC (1%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, and/or transfemorally using snares, retrieval baskets, and sheaths. Complete removal was achieved for 93% of leads, partial for 5%, and 2% were not removed. Risk of incomplete or failed extraction increased with implant duration (P < 0.0001), less experienced physicians (P < 0.0001), ventricular leads (P < 0.005), noninfected patients (P < 0.0005), and younger patients (P < 0.0001). Major complications were reported for 1.4% of patients (< 1% at centers with > 300 cases), minor for 1.7%. Risk of complications increased with number of leads removed (P < 0.005) and with less experienced physicians (P < 0.005); risk of major complications was higher for women (P < 0.01). Given physician experience, appropriate precautions, and appropriate patient selection, contemporary lead removal techniques allow success with low complication rates.Keywords
This publication has 20 references indexed in Scilit:
- Three-Year Experience with a Stylet for Lead Extraction: A Multicenter StudyPacing and Clinical Electrophysiology, 1996
- Atrial "J" Pacing Lead Retention Wire Fracture: Radiographic Assessment, Incidence of Fracture, and Clinical ManagementPacing and Clinical Electrophysiology, 1995
- Five‐Years Experience with Intravascular Lead ExtractionPacing and Clinical Electrophysiology, 1994
- Intravascular Extraction of Chronic Pacemaker Leads: Efficacy and Follow‐UpPacing and Clinical Electrophysiology, 1993
- Complications Associated with Retained Pacemaker LeadsPacing and Clinical Electrophysiology, 1991
- Extraction of implanted transvenous pacing leads: A review of a persistent clinical problemAmerican Heart Journal, 1991
- Intravascular Lead Extraction Using Locking Stylets and SheathsPacing and Clinical Electrophysiology, 1990
- Intravascular Lead Extraction Using Locking Stylets, Sheaths, and Other TechniquesPacing and Clinical Electrophysiology, 1990
- Chronic transvenous pacemaker lead removal using a unique, sequential transvenous systemThe American Journal of Cardiology, 1990
- Incarceration of transvenous pacemaker electrode. Removal by tractionAmerican Heart Journal, 1969