Abstract
Objective To describe the diagnostic performance of SolarScan (Polartechnics Ltd, Sydney, Australia), an automated instrument for the diagnosis of primary melanoma. Design Images from a data set of 2430 lesions (382 were melanomas; median Breslow thickness, 0.36 mm) were divided into a training set and an independent test set at a ratio of approximately 2:1. A diagnostic algorithm (absolute diagnosis of melanoma vs benign lesion and estimated probability of melanoma) was developed and its performance described on the test set. High-quality clinical and dermoscopy images with a detailed patient history for 78 lesions (13 of which were melanomas) from the test set were given to various clinicians to compare their diagnostic accuracy with that of SolarScan. Setting Seven specialist referral centers and 2 general practice skin cancer clinics from 3 continents. Comparison between clinician diagnosis and SolarScan diagnosis was by 3 dermoscopy experts, 4 dermatologists, 3 trainee dermatologists, and 3 general practitioners. Patients Images of the melanocytic lesions were obtained from patients who required either excision or digital monitoring to exclude malignancy. Main Outcome Measures Sensitivity, specificity, the area under the receiver operator characteristic curve, median probability for the diagnosis of melanoma, a direct comparison of SolarScan with diagnoses performed by humans, and interinstrument and intrainstrument reproducibility. Results The melanocytic-only diagnostic model was highly reproducible in the test set and gave a sensitivity of 91% (95% confidence interval [CI], 86%-96%) and specificity of 68% (95% CI, 64%-72%) for melanoma. SolarScan had comparable or superior sensitivity and specificity (85% vs 65%) compared with those of experts (90% vs 59%), dermatologists (81% vs 60%), trainees (85% vs 36%; P =.06), and general practitioners (62% vs 63%). The intraclass correlation coefficient of intrainstrument repeatability was 0.86 (95% CI, 0.83-0.88), indicating an excellent repeatability. There was no significant interinstrument variation (P = .80). Conclusions SolarScan is a robust diagnostic instrument for pigmented or partially pigmented melanocytic lesions of the skin. Preliminary data suggest that its performance is comparable or superior to that of a range of clinician groups. However, these findings should be confirmed in a formal clinical trial.Keywords
This publication has 10 references indexed in Scilit:
- Digital image analysis for diagnosis of cutaneous melanoma. Development of a highly effective computer algorithm based on analysis of 837 melanocytic lesionsBritish Journal of Dermatology, 2004
- Diagnostic and neural analysis of skin cancer (DANAOS). A multicentre study for collection and computer-aided analysis of data from pigmented skin lesions using digital dermoscopyBritish Journal of Dermatology, 2003
- Automated epiluminescence microscopy—tissue counter analysis using CART and 1‐NN in the diagnosis of MelanomaSkin Research and Technology, 2003
- Improved identification of potentially dangerous pigmented skin lesions by computerized image analysis.Archives of Dermatology, 2003
- Digital dermoscopy analysis of atypical pigmented skin lesions: a stepwise logistic discriminant analysis approachSkin Research and Technology, 2002
- Automated diagnosis of pigmented skin lesionsInternational Journal of Cancer, 2002
- Dermoscopic diagnosis by a trained clinician vs. a clinician with minimal dermoscopy training vs. computer-aided diagnosis of 341 pigmented skin lesions: a comparative studyBritish Journal of Dermatology, 2002
- Digital Dermoscopy Analysis and Artificial Neural Network for the Differentiation of Clinically Atypical Pigmented Skin Lesions: A Retrospective StudyJournal of Investigative Dermatology, 2002
- Who removes pigmented skin lesions?: A study of the ratio of melanoma to other benign pigmented tumors removed by different categories of physicians in Australia in 1989 and 1994Journal of the American Academy of Dermatology, 1997
- Automated Instrumentation for the Diagnosis of Invasive Melanoma: Image Analysis of Oil Epiluminescence MicroscopyPublished by Springer Science and Business Media LLC ,1997