Implementation of radon barriers, model development and calculation of radon concentration in indoor air
- 31 March 2010
- journal article
- research article
- Published by SAGE Publications in Journal of Building Physics
- Vol. 34 (3), 195-222
- https://doi.org/10.1177/1744259109358285
Abstract
Norway has some of the highest concentrations of radon in indoor air in the world. Based on large-scale surveys by direct measurements of radon in indoor air it has been estimated that nearly 9% of the housing stock has an annual mean indoor radon concentration which is higher than the current action level of 200 Bq/m3. Preventive measures that focuses on saving energy and avoiding moisture problems in a cold climate, and by not introducing any specific measures to reduce the infiltration of radon and/or balanced ventilation of the indoor air, can lead to high indoor radon concentrations. It is of vital importance that the ground floor structure is as airtight as possible; both to reduce the infiltration of soil gas radon by using, for example, airtight and resistant membranes, and as a premise for other preventive measures to function, for example, sub-slab depressurization systems. Sufficient airtightness may be achieved by using a radon barrier towards the ground, for example, by avoiding perforations and ensuring sufficient airtightness in joints and feed-throughs. Various factors influencing the radon concentration in indoor air are discussed. Based on these factors a simplified but yet versatile and powerful model for calculating the radon concentration in indoor air is presented. Furthermore, the examples are depicted in selected 2 and 3D graphical plots for visualization. By incorporating various and realistic values in a spreadsheet version of the indoor radon concentration model, valuable information about the different parameters influencing the indoor radon level is gained. Hence, the presented model may be utilized as a tool for examining which preventive or remedial measures should be carried out in order to achieve an indoor level of radon below the reference level as set by the authorities. The radon transport into buildings might be dominated by diffusion, pressure driven flow or something in between depending on the actual values of the various parameters. The results of our work indicate that with realistic or typical values of the parameters, most of the transport of radon from the building ground to the indoor air is due to air leakage driven by pressure differences through the construction.Keywords
This publication has 16 references indexed in Scilit:
- Modeling and measuring the indoor radon concentrations in high-rise buildings in Hong KongApplied Radiation and Isotopes, 1999
- Application of a radon model to explain indoor radon levels in a Swedish houseRadiation Measurements, 1999
- The nuclear track detector—A tool in radon measurementsRadiation Measurements, 1997
- Radon measurements in soil to predict indoor radon concentrations in new buildings in an area with unusually high radon levelsScience of The Total Environment, 1995
- Radon gas — where from and what to do?Radiation Measurements, 1995
- Influence of Ventilation Rate on Indoor Radon Concentration in a Test ChamberRadiation Protection Dosimetry, 1994
- Unusually high indoor radon concentrations from a giant rock slideScience of The Total Environment, 1994
- Factors Affecting Indoor Radon Concentrations in the United KingdomHealth Physics, 1993
- Subterranean transport of radon and elevated indoor radon in hilly karst terrainsAtmospheric Environment. Part A. General Topics, 1992
- Radon transport from soil to airReviews of Geophysics, 1992