An energy-discrimination K-edge X-ray computed tomography (CT) system is useful for increasing the contrast resolution of a target region by utilizing contrast media. The CT system has a cadmium telluride (CdTe) detector, and a projection curve is obtained by linear scanning with use of the CdTe detector in conjunction with an X-stage. An object is rotated by a rotation step angle with use of a turntable between the linear scans. Thus, CT is carried out by repetition of the linear scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced with use of charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. For performing energy discrimination, a low-dose-rate X-ray generator for photon counting was developed; the maximum tube voltage and the minimum tube current were 110 kV and 1.0 μA, respectively. In energy-discrimination CT, the tube voltage and the current were 60 kV and 20.0 μA, respectively, and the X-ray intensity was 0.735 μGy/s at 1.0 m from the source and with a tube voltage of 60 kV. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selection of photons with energies just beyond the iodine K-edge energy of 33.2 keV.Keywords
This publication has 18 references indexed in Scilit:
- K-edge angiography utilizing a tungsten plasma X-ray generator in conjunction with gadolinium-based contrast mediaRadiation Physics and Chemistry, 2006
- X-ray Spectra from Weakly Ionized Linear Copper PlasmaJapanese Journal of Applied Physics, 2006
- Characteristic X-ray Generator Utilizing Angle Dependence of Bremsstrahlung X-ray DistributionJapanese Journal of Applied Physics, 2006
- Enhanced K-edge Angiography Utilizing Tantalum Plasma X-ray Generator in Conjunction with Gadolinium-Based Contrast MediaJapanese Journal of Applied Physics, 2005
- Variations in Cerium X-ray Spectra and Enhanced K-Edge AngiographyJapanese Journal of Applied Physics, 2005
- Quasi-Monochromatic Flash X-Ray Generator Utilizing Disk-Cathode Molybdenum TubeJapanese Journal of Applied Physics, 2004
- Development of a two-dimensional imaging system for clinical applications of intravenous coronary angiography using intense synchrotron radiation produced by a multipole wigglerJournal of Synchrotron Radiation, 1998
- Fundamental Study on a Long-Duration Flash X-Ray Generator with a Surface-Discharge TriodeJapanese Journal of Applied Physics, 1994
- Repetitive flash x-ray generator having a high-durability diode driven by a two-cable-type line pulserReview of Scientific Instruments, 1994
- X-ray flash techniquesJournal of Physics E: Scientific Instruments, 1979