Electroanalytical procedures are often subjected to oxygen interferences. However, achieving anaerobic conditions in field analytical chemistry is difficult. In this work, novel enzymatic systems were designed to maintain oxygen-free solutions in open, small volume electrochemical cells and implemented under field conditions. The oxygen removal system consists of an oxidase enzyme, an oxidase-specific substrate, and catalase for dismutation of hydrogen peroxide generated in the enzyme catalyzed oxygen removal reaction. Using cyclic voltammetry, three oxidase enzyme/substrate combinations with catalase were analyzed: glucose oxidase with glucose, galactose oxidase with galactose, and pyranose 2-oxidase with glucose. Each system completely removed oxygen for 1 h or more in unstirred open vessels. Reagents, catalysts, reaction intermediates, and products involved in the oxygen reduction reaction were not detected electrochemically. To evaluate the oxygen removal systems in a field sensing device, a model nitrate biosensor based on recombinant eukaryotic nitrate reductase was implemented in commercial screen-printed electrochemical cells with 200 μL volumes. The products of the aldohexose oxidation catalyzed by glucose oxidase and galactose oxidase deactivate nitrate reductase and must be quenched for biosensor applications. For general application, the optimum catalyst is pyranose 2-oxidase since the oxidation product does not interfere with the biorecognition element.Keywords
This publication has 32 references indexed in Scilit:
- An Oxygen Scavenging System for Improvement of Dye Stability in Single-Molecule Fluorescence ExperimentsBiophysical Journal, 2008
- Amperometric lactate biosensors and their application in (sports) medicine, for life quality and wellbeingMicrochimica Acta, 2007
- Real-Time Observation of RecA Filament Dynamics with Single Monomer ResolutionCell, 2006
- Nitrate reductase for nitrate analysis in waterEnvironmental Chemistry Letters, 2006
- Electrochemical Determination of Nitrate with Nitrate Reductase-Immobilized Electrodes under Ambient AirAnalytical Chemistry, 2005
- tRNA selection and kinetic proofreading in translationNature Structural & Molecular Biology, 2004
- Environmental applications of analytical biosensorsMeasurement Science and Technology, 1996
- Amperometric Detection of Nitrate via a Nitrate Reductase Immobilized and Electrically Wired at the Electrode SurfaceAnalytical Chemistry, 1994
- Facile chemical deoxygenation of micellar solutions for room temperature phosphorescenceAnalytical Chemistry, 1986
- Enzymatic Removal of Oxygen for Polarography and Related MethodsScience, 1953