Nonenhanced Free-Breathing ECG-Gated Steady-State Free Precession 3D MR Angiography of the Renal Arteries: Comparison Between 1.5 T and 3 T
- 1 March 2010
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 194 (3), 794-798
- https://doi.org/10.2214/ajr.09.2814
Abstract
OBJECTIVE. The purpose of our study was to compare the image quality of free-breathing ECG-gated nonenhanced steady-state free precession (SSFP) MR angiography of renal arteries at 1.5 T and 3 T. SUBJECTS AND METHODS. Twenty volunteers (11 men, nine women; mean age, 23.2 ± 2.3 years) without a history of renovascular disease participated in the study. Nonenhanced SSFP MR angiography was performed on all subjects at both 1.5 T and 3 T with a maximum interval of 2 weeks between the imaging sessions. The subjective image quality of axial and coronal maximum-intensity-projection reconstructions of four segments (1, abdominal aorta and ostium of renal artery; 2, main renal artery; 3, segmental branches outside renal parenchyma; 4, segmental branches inside renal parenchyma) was evaluated independently by two radiologists using a 4-point scale (4, excellent; 1, nondiagnostic). Relative signal-to-noise ratio, contrast-to-noise ratio, and maximum visible vessel length of the right and left renal arteries also were determined. RESULTS. No significant difference in image quality at 1.5 T and 3 T was found for segments 1 and 2. The mean image quality for segments 3 and 4 was significantly greater at 3 T (3.88 ± 0.32, 3.17 ± 0.70) than at 1.5 T (3.32 ± 0.73, 2.09 ± 0.81) (p < 0.001). At 3 T, the maximal vessel length of the right (9.85 ± 0.82 cm) and left (8.3 ± 0.79 cm) renal arteries was significantly greater than at 1.5 T (8.94 ± 1.38 cm and 7.58 ± 1.18 cm, respectively). CONCLUSION. Performing nonenhanced SSFP MR angiography at 3 T significantly improves visualization of peripheral renal arterial segments in healthy subjects as compared to 1.5 T.Keywords
This publication has 23 references indexed in Scilit:
- Fast projective carotid MR angiography using arterial spin‐labeled balanced SSFPJournal of Magnetic Resonance Imaging, 2008
- Free‐breathing 3D steady‐state free precession coronary magnetic resonance angiography: Comparison of diaphragm and cardiac fat navigatorsJournal of Magnetic Resonance Imaging, 2008
- Nonenhanced MR AngiographyRadiology, 2008
- Nephrogenic Systemic FibrosisJournal of the American Society of Nephrology, 2006
- Renal Arteries: Comparison of Steady-State Free Precession MR Angiography and Contrast-enhanced MR AngiographyRadiology, 2006
- Gadolinium – a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?Nephrology Dialysis Transplantation, 2006
- High-Spatial-Resolution MR Angiography of Renal Arteries with Integrated Parallel Acquisitions: Comparison with Digital Subtraction Angiography and USRadiology, 2005
- High-Spatial-Resolution 3D Balanced Turbo Field-Echo Technique for MR Angiography of the Renal Arteries: Initial ExperienceRadiology, 2004
- Diagnostic Tests for Renal Artery Stenosis in Patients Suspected of Having Renovascular HypertensionAnnals of Internal Medicine, 2001
- Renal arteriography using gadolinium enhanced 3D MR angiography—clinical experience with the technique, its limitations and pitfallsThe British Journal of Radiology, 2001