Correction of CT artifacts and its influence on Monte Carlo dose calculations
- 21 May 2007
- journal article
- radiation imaging-physics
- Published by Wiley in Medical Physics
- Vol. 34 (6Part1), 2119-2132
- https://doi.org/10.1118/1.2736777
Abstract
Computed tomography (CT) images of patients having metallic implants or dental fillings exhibit severe streaking artifacts. These artifacts may disallow tumor and organ delineation and compromise dose calculation outcomes in radiotherapy. We used a sinogram interpolation metal streaking artifact correction algorithm on several phantoms of exact‐known compositions and on a prostate patient with two hip prostheses. We compared original CT images and artifact‐corrected images of both. To evaluate the effect of the artifact correction on dose calculations, we performed Monte Carlo dose calculation in the EGSnrc/DOSXYZnrc code. For the phantoms, we performed calculations in the exact geometry, in the original CT geometry and in the artifact‐corrected geometry for photon and electron beams. The maximum errors in photon beam dose calculation were found to exceed 25% in original CT images when the standard DOSXYZnrc/CTCREATE calibration is used but less than 2% in artifact‐corrected images when an extended calibration is used. The extended calibration includes an extra calibration point for a metal. The patient dose volume histograms of a hypothetical target irradiated by five photon beams in a hypothetical treatment differ significantly in the original CT geometry and in the artifact‐corrected geometry. This was found to be mostly due to miss‐assignment of tissue voxels to air due to metal artifacts. We also developed a simple Monte Carlo model for a CT scanner and we simulated the contribution of scatter and beam hardening to metal streaking artifacts. We found that whereas beam hardening has a minor effect on metal artifacts, scatter is an important cause of these artifacts.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 29 references indexed in Scilit:
- IMRT head and neck treatment planning with a commercially available Monte Carlo based planning systemPhysics in Medicine & Biology, 2005
- Sensitivity study for CT image use in Monte Carlo treatment planningPhysics in Medicine & Biology, 2005
- Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation enginePhysics in Medicine & Biology, 2005
- Reduction of computed tomography metal artifacts due to the Fletcher-Suit applicator in gynecology patients receiving intracavitary brachytherapyBrachytherapy, 2003
- Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstructionMedical Physics, 2002
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- Metal streak artifacts in X-ray computed tomography: a simulation studyIEEE Transactions on Nuclear Science, 1999
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- Deblurring subject to nonnegativity constraintsIEEE Transactions on Signal Processing, 1992
- Optimal short scan convolution reconstruction for fan beam CTMedical Physics, 1982