Impact of Valvular Calcification on the Diagnostic Accuracy of Transesophageal Echocardiography for the Detection of Congenital Aortic Valve Malformation
- 1 August 2007
- journal article
- Published by Wiley in Echocardiography
- Vol. 24 (7), 745-749
- https://doi.org/10.1111/j.1540-8175.2007.00459.x
Abstract
Degeneration of congenital bicuspid or unicuspid aortic valves can progress more rapidly than that of tricuspid valves, and an early diagnosis significantly impacts decision making and outcome. We hypothesized that the extent of valvular calcification would negatively influence the diagnostic accuracy of multiplane transesophageal echocardiography (TEE) for the diagnosis of congenital aortic valve disease. TEE was performed in 57 patients undergoing aortic valve replacement surgery for aortic stenosis (n = 46), pure regurgitation (n = 9), or significant regurgitation with less than severe aortic stenosis (n = 2). The degree of aortic valve calcification and the number of valve cusps were determined at surgery. Surgical inspection confirmed 14 bicuspid and 43 tricuspid aortic valves. Sensitivity and specificity of TEE for the diagnosis of congenital aortic valve malformation was 93% (13/14) and 91% (39/43) (P = 0.0001), respectively. In patients with no or mild aortic valve calcification (n = 13), sensitivity and specificity of TEE for the diagnosis of congenitally malformed aortic valve was 100% (5/5) and 100% (8/8) (P = 0.001), respectively. In patients with moderate or marked aortic valve calcification (n = 44), sensitivity and specificity of TEE for the diagnosis of congenitally malformed aortic valve was 89% (8/9) and 89% (31/35) (P<0.0001), respectively. In this subgroup of 44 patients, there were four false-positive and one false-negative diagnoses due to valvular calcification. Although TEE is highly sensitive and specific for the detection of congenital aortic valve malformations, presence of moderate or marked calcification of the aortic valve may result in false positive and false negative diagnoses.Keywords
This publication has 18 references indexed in Scilit:
- Planimetry of orifice area in aortic stenosis using multiplane transesophageal ecocardiographyJournal of the American College of Cardiology, 1993
- Progression of aortic valve dysfunction in 51 adult patients with congenital bicuspid aortic valve: assessment and follow up by Doppler echocardiography.Published by BMJ ,1993
- Aortic valve regurgitation and the congenitally bicuspid aortic valve: a clinico-pathological correlation.Heart, 1992
- Association of aortic dilation with regurgitant, stenotic and functionally normal bicuspid aortic valvesJournal of the American College of Cardiology, 1992
- Risk factors for aortic dissection: A necropsy study of 161 casesThe American Journal of Cardiology, 1984
- Accuracy of 2-dimensional echocardiographic diagnosis of congenitally bicuspid aortic valve: Echocardiographic-anatomic correlation in 115 patientsThe American Journal of Cardiology, 1983
- Congenital bicuspid aortic valve after age 20The American Journal of Cardiology, 1977
- The congenitally bicuspid aortic valve: A study of 85 autopsy casesThe American Journal of Cardiology, 1970
- The Structure of the Aortic Valve in Clinically Isolated Aortic StenosisCirculation, 1970
- Calcific aortic stenosis and congenital bicuspid aortic valves.Heart, 1968