Threshold segmentation for PET target volume delineation in radiation treatment planning: The role of target‐to‐background ratio and target size
- 7 March 2008
- journal article
- Published by Wiley in Medical Physics
- Vol. 35 (4), 1207-1213
- https://doi.org/10.1118/1.2870215
Abstract
A multivariable approach was adopted to study the dependence of the percentage threshold [TH(%)] used to define the boundaries of 18F-FDG positive tissue on emission scan duration (ESD) and activity at the start of acquisition (Aacq) for different target sizes and target-to-background (T/B) ratios. An anthropomorphic model, at least for counting rate characteristics, was used to study this dependence in conditions resembling the ones that can be encountered in the clinical studies. An annular ring of water bags of 3 cm thickness was fitted over an International Electro-technical Commission (IEC) phantom in order to obtain counting rates similar to those found in average patients. The scatter fraction of the modified IEC phantom was similar to the mean scatter fraction measured on patients, with a similar scanner. A supplemental set of microhollow spheres was positioned inside the phantom. The NEMA NU 2-2001 scatter phantom was positioned at the end of the IEC phantom to approximate the clinical situation of having activity that extends beyond the scanner field of view. The phantoms were filled with a solution of water and 18F (12 kBq/mL) and the spheres with various T/B ratios of 22.5, 10.3, and 3.6. Sequential imaging was performed to acquire PET images with varying background activity concentrations of about 12, 9, 6.4, 5.3, and 3.1 kBq/mL. The ESD was set to 60, 120, 180, and 240 s/bed. Data were fitted using two distinct multiple linear regression models for sphere ID < or = 10 mm and sphere ID > 10 mm. The fittings of both models were good with an R2 of 0.86 in both cases. Neither ESD nor Aacq resulted as significant predictors of the TH(%). For sphere ID < or =10 mm the target size was the most significant predictor of the TH(%), followed by the T/B ratio, while for sphere ID > 10 mm the explanatory power of the target size and T/B ratio were reversed, the T/B ratio being now the most important predictor of the TH(%). Both the target size and T/B ratio play a major role in explaining the variance of the TH(%), throughout the whole range of target sizes and T/B ratios examined. Thus, algorithms aimed at automatic threshold segmentation should incorporate both variables with a relative weight which critically depends on target size.Keywords
This publication has 21 references indexed in Scilit:
- Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PETPhysics in Medicine & Biology, 2007
- A gradient-based method for segmenting FDG-PET images: methodology and validationEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- Assessment of 18F PET signals for automatic target volume definition in radiotherapy treatment planningRadiotherapy and Oncology, 2006
- Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusionInternational Journal of Radiation Oncology*Biology*Physics, 2006
- Automated functional image-guided radiation treatment planning for rectal cancerInternational Journal of Radiation Oncology*Biology*Physics, 2005
- FDG-PET/CT-guided intensity modulated head and neck radiotherapy: A pilot investigationHead & Neck, 2005
- F-18 FDG PET-CT fusion in radiotherapy treatment planning for head and neck cancerHead & Neck, 2005
- Hybrid PET-CT simulation for radiation treatment planning in head-and-neck cancers: A brief technical reportInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Defining a radiotherapy target with positron emission tomographyInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Impact of FDG-PET on radiation therapy volume delineation in non–small-cell lung cancerInternational Journal of Radiation Oncology*Biology*Physics, 2004