In this paper, the authors describe the design of a bendable robotic tip for semi-autonomous colonoscopy called COLOBOT. It is a flexible robotic manipulator made of silicone rubber in view of the compact size and biocompatibility. The outer diameter of the tip is 17 mm which is lesser than the average diameter of colon (20 mm). Three servo-valves are used to control the pressure of each chamber of this tip to obtain its flexible movement. The experimental results of this new prototype show that it can bend until 120 degrees under the pressure of 2 bar. Based on the geometric deformation and a nonlinear analysis of the silicone behavior, a direct kinematic model analogous to the forward kinematics of a conventional industrial robot kinematics chain has been put forward. The proposed kinematic model of this bendable tip is an extended model of classical models found for such a mechanism. At first a polynomial approximation is used to characterize the non linear behavior of each chamber of the actuator. Next the coupling phenomena between each chamber are highlighted through experimental tests. A new correction parameter is then proposed to take into account these interactions and a non linear optimization is made to compute this coefficient. Finally, the proposed kinematic model is experimentally validatedKeywords
This publication has 13 references indexed in Scilit:
- Human-Robot Shared Control for Robot-Assisted Endoscopy of the Spinal CordPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2006
- Kinematics for multisection continuum robotsIEEE Transactions on Robotics, 2006
- Shape memory alloy clamping devices of a capsule for monitoring tasks in the gastrointestinal tractJournal of Micromechanics and Microengineering, 2005
- The development of a bendable colonoscopic tipPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2004
- Continuum robots - a state of the artPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Micro active catheter system with multi degrees of freedomPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Design of slim slime robot and its gait of locomotionPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Design of a vision-guided microrobotic colonoscopy systemAdvanced Robotics, 2000
- The AMADEUS dextrous subsea hand: design, modeling, and sensor processingIEEE Journal of Oceanic Engineering, 1999
- Automation of colonoscopy. II. Visual control aspectsIEEE Engineering in Medicine and Biology Magazine, 1998