Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Open Access
- 27 March 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 45 (4), 595-604
- https://doi.org/10.1002/mrm.1081
Abstract
Noise properties, the signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and signal responses were compared during functional activation of the human brain at 1.5 and 3.0 T. At the higher field spiral gradient‐echo (GRE) brain images revealed an average gain in SNR of 1.7 in fully relaxed and 2.2 in images with a repetition time (TR) of 1.5 sec. The tempered gain at longer TRs reflects the fact that the physiological noise depends on the signal strength and becomes a larger fraction of the total noise at 3.0 T. Activation of the primary motor and visual cortex resulted in a 36% and 44% increase of “activated pixels” at 3.0 T, which reflects a greater sensitivity for the detection of activated gray matter at the higher field. The gain in the CNR exhibited a dependency on the underlying tissue, i.e., an increase of 1.8× in regions of particular high activation‐induced signal changes (presumably venous vessels) and of 2.2× in the average activated areas. These results demonstrate that 3.0 T provides a clear advantage over 1.5 T for neuroimaging of homogeneous brain tissue, although stronger physiological noise contributions, more complicated signal features in the proximity of strong susceptibility gradients, and changes in the intrinsic relaxation times may mediate the enhancement. Magn Reson Med 45:595–604, 2001.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (Kr 1896/1-1, Ka 1419/1-1)
- NIH NCRR (RR09784)
This publication has 24 references indexed in Scilit:
- Comparison of 3D BOLD Functional MRI with Spiral Acquisition at 1.5 and 4.0 TNeuroImage, 1999
- Experimental determination of the BOLD field strength dependence in vessels and tissueMagnetic Resonance in Medicine, 1997
- Inflow versus deoxyhemoglobin effects in bold functional MRI using gradient echoes at 1.5 TNMR in Biomedicine, 1994
- Brain or vein-oxygenation or flow? On signal physiology in functional MRI of human brain activationNMR in Biomedicine, 1994
- Localization of brain function using magnetic resonance imagingTrends in Neurosciences, 1994
- Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical modelBiophysical Journal, 1993
- Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPIMagnetic Resonance in Medicine, 1993
- MR Contrast Due to Microscopically Heterogeneous Magnetic Susceptibility: Numerical Simulations and Applications to Cerebral PhysiologyMagnetic Resonance in Medicine, 1991
- The field dependence of NMR imaging. II. Arguments concerning an optimal field strengthMagnetic Resonance in Medicine, 1986
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986