Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass Spectrometry
Open Access
- 1 February 2010
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 56 (2), 291-305
- https://doi.org/10.1373/clinchem.2009.138420
Abstract
Background: Multiple reaction monitoring mass spectrometry (MRM-MS) of peptides with stable isotope–labeled internal standards (SISs) is increasingly being used to develop quantitative assays for proteins in complex biological matrices. These assays can be highly precise and quantitative, but the frequent occurrence of interferences requires that MRM-MS data be manually reviewed, a time-intensive process subject to human error. We developed an algorithm that identifies inaccurate transition data based on the presence of interfering signal or inconsistent recovery among replicate samples. Methods: The algorithm objectively evaluates MRM-MS data with 2 orthogonal approaches. First, it compares the relative product ion intensities of the analyte peptide to those of the SIS peptide and uses a t-test to determine if they are significantly different. A CV is then calculated from the ratio of the analyte peak area to the SIS peak area from the sample replicates. Results: The algorithm identified problematic transitions and achieved accuracies of 94%–100%, with a sensitivity and specificity of 83%–100% for correct identification of errant transitions. The algorithm was robust when challenged with multiple types of interferences and problematic transitions. Conclusions: This algorithm for automated detection of inaccurate and imprecise transitions (AuDIT) in MRM-MS data reduces the time required for manual and subjective inspection of data, improves the overall accuracy of data analysis, and is easily implemented into the standard data-analysis work flow. AuDIT currently works with results exported from MRM-MS data-processing software packages and may be implemented as an analysis tool within such software.Keywords
Funding Information
- National Cancer Institute (U24 CA126476, R01 CA126219)
- National Heart Lung and Blood Institute (R01 HL096738-01)
This publication has 46 references indexed in Scilit:
- Full Dynamic Range Proteome Analysis of S. cerevisiae by Targeted ProteomicsCell, 2009
- Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasmaNature Biotechnology, 2009
- Absolute Quantification of Phosphorylation on the Kinase Activation Loop of Cellular Focal Adhesion Kinase by Stable Isotope Dilution Liquid Chromatography/Mass SpectrometryAnalytical Chemistry, 2009
- Expediting the Development of Targeted SRM Assays: Using Data from Shotgun Proteomics to Automate Method DevelopmentJournal of Proteome Research, 2009
- MRMer, an Interactive Open Source and Cross-platform System for Data Extraction and Visualization of Multiple Reaction Monitoring ExperimentsMolecular & Cellular Proteomics, 2008
- Accurate Inclusion Mass ScreeningMolecular & Cellular Proteomics, 2008
- Selected reaction monitoring for quantitative proteomics: a tutorialMolecular Systems Biology, 2008
- Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope DilutionMolecular & Cellular Proteomics, 2007
- Antibody-based enrichment of peptides on magnetic beads for mass-spectrometry-based quantification of serum biomarkersAnalytical Biochemistry, 2007
- Protein biomarker discovery and validation: the long and uncertain path to clinical utilityNature Biotechnology, 2006