Pre-concentration of copper, cobalt and nickel with 3-methyl-1-phenyl-4-stearoyl-5-pyrazolone loaded on silica gel

Abstract
3-Methyl-1-phenyl-4-stearoyl-5-pyrazolone loaded on to silica gel was used as a pre-concentration reagent for copper, cobalt and nickel prior to atomic absorption spectrometric determination. Both batch and column methods were used for the concentration of the above metals. These metals are quantitatively retained on the proposed adsorbent above pH 4. The adsorption-elution cycle can be repeated ten times with no observable decline in the efficiency of the adsorbent. As there are no observable effects due to changes in the volume of sample solution up to a volume of 1 l, a concentration factor of 40 can be achieved. The method has been applied to samples of sodium chloride solution and tap water.