Effects of circumferential or segmental pulmonary vein ablation for paroxysmal atrial fibrillation on cardiac autonomic function
- 1 December 2006
- journal article
- research article
- Published by Elsevier BV in Heart Rhythm
- Vol. 3 (12), 1428-1435
- https://doi.org/10.1016/j.hrthm.2006.08.025
Abstract
Circumferential and segmental pulmonary vein ablations are two established treatment strategies for ablation of atrial fibrillation. Both techniques require the application of radiofrequency current at anatomical sites that are close to autonomic ganglia. However, the effects of current pulmonary vein ablation techniques on cardiac autonomic function are unknown. The purpose of this study was to analyze the short- and long-term effects of circumferential and segmental pulmonary vein ablation on cardiac autonomic function. One hundred patients with highly symptomatic atrial fibrillation were randomly assigned to undergo either circumferential or segmental pulmonary vein ablation. Holter recordings were recorded at baseline and at regular intervals for up to 1 year after ablation. Autonomic function was assessed by deceleration capacity and acceleration capacity of heart rate as well as by standard measures of heart rate variability. In the circumferential pulmonary vein ablation group, deceleration capacity and acceleration capacity decreased highly significantly from 5.7 +/- 2.1 ms and -8.0 +/- 1.9 ms at baseline to 3.3 +/- 1.8 ms and -5.5 +/- 2.3 ms directly after ablation, respectively (P<.00001). Impairment of deceleration capacity and acceleration capacity was present up to 1 year after ablation. In the segmental pulmonary vein ablation group, deceleration capacity and acceleration capacity decreased from 5.8 +/- 2.0 ms and -7.8 +/- 1.6 ms at baseline to 3.4 +/- 1.2 ms and -6.0 +/- 2.4 ms directly after ablation (P<.00001), respectively. However, deceleration capacity and acceleration capacity returned to baseline values within 1 month. Circumferential and segmental pulmonary vein ablations induce an immediate decrease of autonomic function. However, while this decrease is only transient with segmental pulmonary vein ablation, it persists with circumferential pulmonary vein ablation for at least 1 year.Keywords
This publication has 32 references indexed in Scilit:
- Circumferential Pulmonary-Vein Ablation for Chronic Atrial FibrillationNew England Journal of Medicine, 2006
- Freedom From Atrial Tachyarrhythmias After Catheter Ablation of Atrial FibrillationCirculation, 2005
- Mortality, morbidity, and quality of life after circumferential pulmonary vein ablation for atrial fibrillationJournal of the American College of Cardiology, 2003
- Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial FibrillationCirculation, 2002
- Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein AblationCirculation, 2001
- Circumferential Radiofrequency Ablation of Pulmonary Vein OstiaCirculation, 2000
- Electrophysiological End Point for Catheter Ablation of Atrial Fibrillation Initiated From Multiple Pulmonary Venous FociCirculation, 2000
- Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping SystemCirculation, 1999
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998
- Successful Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 1994