Reliability of simple portable tests of physical performance in older people after hip fracture
- 1 August 2005
- journal article
- clinical trial
- Published by SAGE Publications in Clinical Rehabilitation
- Vol. 19 (5), 496-504
- https://doi.org/10.1191/0269215505cr833oa
Abstract
Objective: To investigate the test–retest reliability of measures of strength, balance, gait and functional performance when used with older people following hip fracture. Subjects: Thirty people (16 hospital inpatients and 14 community dwellers). Design: Subjects underwent two assessments: one day apart for the hospital inpatients and one week apart for the community dwellers. Measurement: Strength (dynamometer, sphygmomanometer, spring balance, lateral step-up ability), balance (sway-meter, Functional Reach Test, single leg stance time, Step Test), gait (timed 6-m walk with steps taken, base of support and step length), and functional performance (PPME total score and timed supine-to-sit and sit-to-stand) were measured. Results: Eleven of the 14 continuously scaled measurement tools achieved excellent reliability (intraclass correlation coefficient (ICC)>0.75) for one or more tests. A hand-held dynamometer was found to be the tool with the highest test–retest reliability for measuring hip muscle strength (ICC (3,1) 0.86 for affected hip abduction). For measurement of knee extension strength, a spring balance (ICC (3,1) 0.94 affected leg) was the most reliable. For testing balance, the Step Test (ICC (3,1) 0.94 for stepping with affected leg) and Functional Reach Test (ICC (3,1) 0.89) had the highest test–retest reliability. The ICC (3,1) values were 0.97 for walking velocity (comfortable pace) and 0.96 for the total score of the Physical Performance and Mobility Examination. Conclusion: The test–retest reliability of a number of simple measures of physical performance is excellent when used with this population.Keywords
This publication has 49 references indexed in Scilit:
- Reliability and sensitivity to change assessed for a summary measure of lower body functionJournal of Clinical Epidemiology, 2002
- Outcome of Total Hip ReplacementClinical Orthopaedics and Related Research, 2001
- Practical measure for evaluating functional outcomes post hip fractureInternational Journal of Rehabilitation Research, 2000
- NORMAL VARIABILITY OF POSTURAL MEASURES: IMPLICATIONS FOR THE RELIABILITY OF RELATIVE BALANCE PERFORMANCE OUTCOMESJournal of Rehabilitation Medicine, 1998
- Physical performance measures for the elderly rehabilitated at homeInternational Journal of Rehabilitation Research, 1997
- Predictors for recurrent falls among the home-dwelling elderlyScandinavian Journal of Primary Health Care, 1995
- Modified sphygmomanometer versus strain gauge hand-held dynamometerArchives of Physical Medicine and Rehabilitation, 1991
- ELGAM –- Extra-laboratory gait assessment method: Identification of risk factors for falls among the elderly at homeInternational Disability Studies, 1990
- A PROSPECTIVE TRIAL OF SERIAL GAIT SPEED AS A MEASURE OF REHABILITATION IN THE ELDERLYAge and Ageing, 1988
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960